August 28, 2015Sterlitech is proud to announce that new nanofiltration, ultrafiltration, and microfiltration membranes from Nanostone Water are now available for purchase on our website. These new membranes expand our selection to cover a wider selection of potential applications and are sold in variety of test sizes and sheets.  Contact us to learn more about our new membranes from Nanostone or check out tables below.
Nanostoneâ„¢ Nanofiltration Membranes
ÂSeries NF4 NF8 Feed NA NA Type Partial Desal, Sulfate Removal Partial Desal pH Range 3-10 3-10 Flux (GFD/psi) 46/150 77/150 MWCO (Daltons) ~150 ~300 Polymer TFC TFC Nanostoneâ„¢ Ultrafiltration Membranes
Series PE5 PE10HR PS35 PA200 PV400 Feed Whey/Milk Protein Whey/Milk Protein Food/Beverage Oily Wastewater Oily Wastewater Type Concentration, Isolation Concentration, Isolation Clarification Separation Separation pH Range (25 °C) 2-10 2-10 2-10 4-10.5 2-10 Flux (lmh/bar) 58 100 1530 350 580 MWCO (Daltons) 6,000 10,000 20,000 100,000 100,000 -
August 28, 2015
Our specialty site, the Glass Fiber Store, is now closed.  When it went live in 2011, it was the place to find best selection of glass fiber filters from Sterlitech and Advantec. The products in the Glass Fiber Store have been integrated into our main site. If you’re looking for something that used to be there, try the following links:
- Glass Fiber Filters
- Extraction Thimbles
- Cellulose Filter Papers
-
August 28, 2015
First announced this past spring, the Botanical Extraction section of our website is now up and running! This section houses everything you need to make a complete, basic vacuum filtration system for herbal/botanical extracts including vacuum filter holders, membrane filters, trap bottles or flasks, and vacuum pumps. You can also find optional accessories, such as manifolds, that can be used to modify the filtration process to best suit the project requirements and throughput volume. If you have a need to perform any of the following applications:
- Cold-filtration to remove lipids or waxes, often called winterizing
- Clarification or plant debris removal
- Bacterial removal (using 0.2 or 0.45 micron PES filters)
- Batch processing with manifolds
- Ethanol washing
Then head to our Specialty Applications Section to find the best equipment to work with your botanical extraction process. Â
-
August 04, 2015
The AD line of reverse osmosis membranes from GE is being discontinued. At this time, these membranes do not have any direct replacements, although we still carry other GE membranes which may be suitable for your application.  To aid comparison and help you select a possible replacement, the table below includes the technical specifications of the GE membranes we offer:  GE Osmonics™
Â
Series AD AG AK CE SE SG Feed Seawater Brackish Water Brackish Water Brackish Water Industrial/Wastewater Industrial/Wastewater Type High Rejection Reactive Silica Removal Low Energy Chlorine Resistant Chlorine Resistant, High Pressure Chlorine Resistant pH Range (25°C) 1-11 1-11 1-11 2-8 1-11 1-11 Flux (gfd)/psi 15/800 26/225 26/115 23.5/420 22/425 22/225 NaCl Rejection 99.5% 95.5% 99.0% 97.0% 98.9% 98.2% MWCO (Daltons) 0 0 0 0 0 0 Polymer Polyamide Polyamide Polyamide Cellulose Acetate Thin Film Thin Film We still have very limited quantities available for purchase.  If you need assistance finding
-
July 28, 2015
Heartworms (Dirofilaria immitis) are a species of parasitic roundworms that primarily infect dogs, but can also infect cats, wild canids, and, in rare cases, even humans. They are found in every state in the country and spread from one host to the next through mosquito bites, which deposit larval heartworms into the new host when they feed. Since their lifecycle depends on mosquitos, infection rates are on the rise as human activities, such as irrigation and urban development, create new habitats suitable for mosquitos. Heartworm infections develop slowly, with symptoms often presenting themselves only months past since the initial transmission.
The first symptoms are innocuous enough, just a slight cough. As the worms grow and lodge themselves in the arteries leading into the heart and lungs, the coughing becomes worse and persistent. The dog will exhibit difficulty breathing and a reluctance to exercise, which gets worse as time goes on. Eventually, a severe infection of heartworms
-
July 28, 2015
(Updated Feb, 2017) If you were to casually browse through Sterlitech's website, you may find that we have an incredible range of filter options. The casual browser may certainly find themselves overwhelmed looking for the right filter for their application. One of the most important aspects of filter selection is pore size, which determines the size of largest particles that can pass through the filter. Pore sizes are usually placed in one of two categories: nominal or absolute. So what's the difference? Nominal pore sizes A nominal pore size rating refers to a filter capable of preventing passage of a minimum percentage (usually between 60% and 90%)of solid particles of greater than the stated pore size, which is normally expressed in micrometers or microns. Conditions during filtration, such as operating pressure, shape of the particles and the concentration of particles, have a significant effect on the retention of the filters. Sterlitech's glass and quartz fiber filters have nominal
-
July 22, 2015
Sterlitech will be attending the 42nd Annual NAOSMM Conference and Trade Show! From July 26 - 31, Kristina and Brandon will be on hand at Booth #83 to answer your questions about Sterlitech's laboratory equipment and filters. If you want to send them your questions ahead of time, feel free to shoot them an email: Kristina Shahbazian: [email protected] Brandon Nolan: [email protected]
-
July 08, 2015
Here's a new animation showing the basics of operating Sterlitech's Sepa CF Membrane Test System. Each test system allows users to simulate the dynamics of larger membrane filtration systems by manipulating the control valves to achieve the desired pressure and flow rates. The system is equipped with one or two Sepa CF Cells and a suite of in-line sensors that automatically record and display the experimental data in real time. All Sepa CF test systems are individually manufactured according to the customer's requirements. Contact us to learn more.
-
June 29, 2015
Sterlitech Corporation has been providing the best in laboratory filtration products and equipment for over 14 years. Â For 13 of those years, Shiela Naegele has been there, helping Sterlitech grow into the industry-leading company that it is today. Â She started here manufacturing our silver membrane filters but has since worn nearly every hat she could think to put on, including shipping, marketing, quality control, and receivables. Â These days, her primary focus is in procurement. Â In short, if you have ever ordered anything from Sterlitech in the last decade, Shiela probably had a hand in making sure that you receive a quality product on time, and for the best price we can offer.
-
June 29, 2015
Sterlitech Corporation is proud to offer a new range of compact, quiet, and affordable vacuum sources with the new TLD3000 and TLD5000 diaphragm vacuum pumps. Perfectly suited for vacuum filtration in laboratory analytical procedures, the new pumps require little to no maintenance, built with polytetrafluoroethylene (PTFE) contact surfaces for broad chemical compatibility. With a 1/7 horsepower motor, The TLD3000 vacuum pump can deliver 22 in-Hg of vacuum and 20 L/min of free air displacement. The bleach-resistant TLD5000 vacuum model has a 1/5 horsepower motor for a maximum vacuum of 24 in-Hg and a free air displacement of 37 L/min. This larger vacuum model has a maximum pressure of 18psig and can be used as a pressure pump. Both vacuum pumps feature liquid inlet traps, vacuum regulators and PTFE diaphragms rated 12,000 hours of use.
Designed with the scientist in mind, these new vacuum pumps have a small lab footprint and are extremely durable for frequent use even in the most demanding