Explore our new PFAS-Free products designed specifically for PFAS testing!
Hydrophilic Polycarbonate Membranes
Hydrophilic Polycarbonate Membrane Filter For Laboratory Filtration, Filtration Microbiology

Standard, PVP-treated, polycarbonate track etch (PCTE) membrane filters are our lowest non-specific binding membranes; hydrophilic, exceptionally strong, and extractable-minimizing properties make them ideal for blood assays, high-purity, and general filtration. 

Our hydrophilic PCTE membranes are produced from a a two-step, quality-assured, proprietary manufacturing process delivering consistent products with pore uniformity, predictable flow rates, and trusted particle retention levels. A single, integral, microporous polycarbonate film is used to produce the membranes and provide them with their thin, translucent, structure and the glass-like surface characteristics that enable superior particle visibility and easy microscopic analysis. These PCTE membranes are coated with polyvinylpyrrolidone to enhance the filter's ability process aqueous and alcoholic samples*. Their pores are absolutely-rated, precisely cylindrical, and narrowly distributed, allowing their surfaces to capture 100% of particles larger than pore sizes.

*The PCTE should not be allowed to dry after being wet, or it may lose its hydrophilicity.

Start with a custom PCTE membrane sample pack here.

We provide the filters and technical support to help you take your breakthrough product from an idea to a prototype, to commercial scale.

SKU Product Name Pore Size Diameter (mm) Pack Size Membrane Color Est Ship Price
1270011 Polycarbonate (PCTE) Membrane Filters, 0.03 Micron, 76mm, 30/Pk 0.03 76 30 5-7 days
$316.87
PCT00113100 Polycarbonate (PCTE) Membrane Filters, 0.01 Micron, 13mm, 100/Pk 0.01 13 100 1-2 days
$174.73
PCT00125100 Polycarbonate (PCTE) Membrane Filters, 0.01 Micron, 25mm, 100/Pk 0.01 25 100 1-2 days
$198.41
PCT00147100 Polycarbonate (PCTE) Membrane Filters, 0.01 Micron, 47mm, 100/Pk 0.01 47 100 1-2 days
$318.36
PCT00114220 Polycarbonate (PCTE) Membrane Filters, 0.01 Micron, 142mm, 20/PK 0.01 142 20 1-2 days
$300.46
PCT00120030 Polycarbonate (PCTE) Membrane Filters, 0.01 Micron, 200 x 250mm, 30/Pk 0.01 200 x 250 30 1-2 days
$959.49
PCT0013001 Polycarbonate (PCTE) Membrane Filters, 0.01 Micron, 300 x 3000mm, 1/pk 0.01 300 x 3000 1 1-2 days
$565.62
PCT00313100 Polycarbonate (PCTE) Membrane Filters, 0.03 Micron, 13mm, 100/Pk 0.03 13 100 1-2 days
$174.73
PCT00325100 Polycarbonate (PCTE) Membrane Filters, 0.03 Micron, 25mm, 100/Pk 0.03 25 100 1-2 days
$193.98
PCT00347100 Polycarbonate (PCTE) Membrane Filters, 0.03 Micron, 47mm, 100/Pk 0.03 47 100 1-2 days
$318.36
PCT0039030 Polycarbonate (PCTE) Membrane Filters, 0.03 Micron, 90mm, 30/Pk 0.03 90 30 1-2 days
$316.87
PCT00314220 Polycarbonate (PCTE) Membrane Filters, 0.03 Micron, 142mm, 20/Pk 0.03 142 30 1-2 days
$373.15
PCT00329320 Polycarbonate (PCTE) Membrane Filters, 0.03 Micron, 293mm, 20/Pk 0.03 293 20 1-2 days
$708.93
PCT00320030 Polycarbonate (PCTE) Membrane Filters, 0.03 Micron, 200 x 250mm, 30/Pk 0.03 200 x 250 30 1-2 days
$894.33
PCT0033001 Polycarbonate (PCTE) Membrane Filters, 0.03 Micron, 300 x 3000mm, 1/Pk 0.03 300 x 3000 1 1-2 days
$536.01
PCT00513100 Polycarbonate (PCTE) Membrane Filters, 0.05 Micron, 13mm, 100/Pk 0.05 13 100 1-2 days
$174.73
PCT00525100 Polycarbonate (PCTE) Membrane Filters, 0.05 Micron, 25mm, 100/Pk 0.05 25 100 1-2 days
$183.61
PCT00547100 Polycarbonate (PCTE) Membrane Filters, 0.05 Micron, 47mm, 100/Pk 0.05 47 100 1-2 days
$318.36
PCT0057630 Polycarbonate (PCTE) Membrane Filters, 0.05 Micron, 76mm, 30/Pk 0.05 76 30 1-2 days
$228.04
PCT0059030 Polycarbonate (PCTE) Membrane Filters, 0.05 Micron, 90mm, 30/Pk 0.05 90 30 1-2 days
$228.04
PCT00514220 Polycarbonate (PCTE) Membrane Filters, 0.05 Micron, 142mm, 20/Pk 0.05 142 20 1-2 days
$373.15
PCT00529320 Polycarbonate (PCTE) Membrane Filters, 0.05 Micron, 293mm, 20/Pk 0.05 293 20 1-2 days
$708.93
PCT00520030 Polycarbonate (PCTE) Membrane Filters, 0.05 Micron, 200 x 250mm, 30/Pk 0.05 200 x 250 30 1-2 days
$894.32
PCT0053001 Polycarbonate (PCTE) Membrane Filters, 0.05 Micron, 300 x 3000mm, 1/Pk 0.05 300 x 3000 1 1-2 days
$557.08
PCT00813100 Polycarbonate (PCTE) Membrane Filters, 0.08 Micron, 13mm, 100/Pk 0.08 13 100 1-2 days
$174.73
PCT00825100 Polycarbonate (PCTE) Membrane Filters, 0.08 Micron, 25mm, 100/Pk 0.08 25 100 1-2 days
$183.61
PCT00847100 Polycarbonate (PCTE) Membrane Filters, 0.08 Micron, 47mm, 100/Pk 0.08 47 100 1-2 days
$318.36
PCT087630 Polycarbonate (PCTE) Membrane Filters, 0.8 Micron, 76mm, 30/Pk 0.8 76 30 1-2 days
$134.74
PCT0089030 Polycarbonate (PCTE) Membrane Filters, 0.08 Micron, 90mm, 30/Pk 0.08 90 30 Contact Us
$228.04
PCT00814220 Polycarbonate (PCTE) Membrane Filters, 0.08 Micron, 142mm, 20/Pk 0.08 142 20 1-2 days
$373.15
PCT00829320 Polycarbonate (PCTE) Membrane Filters, 0.08 Micron, 293mm, 20/Pk 0.08 293 20 1-2 days
$708.93
PCT00820030 Polycarbonate (PCTE) Membrane Filters, 0.08 Micron, 200 x 250mm, 30/Pk 0.08 200 x 250 30 1-2 days
$818.32
PCT0113100 Polycarbonate (PCTE) Membrane Filters, 0.1 Micron, 13mm, 100/Pk 0.1 13 100 1-2 days
$134.74
PCT0125100 Polycarbonate (PCTE) Membrane Filters, 0.1 Micron, 25mm, 100/Pk 0.1 25 100 1-2 days
$154.00
PCT0147100 Polycarbonate (PCTE) Membrane Filters, 0.1 Micron, 47mm, 100/Pk 0.1 47 100 1-2 days
$235.43
PCT017630 Polycarbonate (PCTE) Membrane Filters, 0.1 Micron, 76mm, 30/Pk 0.1 76 30 1-2 days
$170.28
PCT0176100 Polycarbonate (PCTE) Membrane Filters, 0.1 Micron, 76mm, 100/Pk 0.1 76 100 3-4 weeks
$312.44
PCT019030 Polycarbonate (PCTE) Membrane Filters, 0.1 Micron, 90mm, 30/Pk 0.1 90 30 1-2 days
$170.28
PCTE0820030 Polycarbonate (PCTE) Membrane Filters, 0.8 Micron, 24 Micron Thickness, 200 x 250mm, 30/Pk 0.8 200 x 250 30 1-2 days
$1,078.49
PCT0114220 Polycarbonate (PCTE) Membrane Filters, 0.1 Micron, 142mm, 20/Pk 0.1 142 20 1-2 days
$288.73
PCT0129320 Polycarbonate (PCTE) Membrane Filters, 0.1 Micron, 293mm, 20/Pk 0.1 293 20 1-2 days
$708.93
PCT0120030 Polycarbonate (PCTE) Membrane Filters, 0.1 Micron, 200 x 250mm, 30/Pk 0.1 200 x 250 30 1-2 days
$845.47
PCT013001 Polycarbonate (PCTE) Membrane Filters, 0.1 Micron, 300 x 3000mm, 1/Pk 0.1 300 x 3000 1 1-2 days
$499.01
PCT0213100 Polycarbonate (PCTE) Membrane Filters, 0.2 Micron, 13mm, 100/Pk 0.2 13 100 1-2 days
$85.89
PCT0225100 Polycarbonate (PCTE) Membrane Filters, 0.2 Micron, 25mm, 100/Pk 0.2 25 100 1-2 days
$96.24
PCT0247100 Polycarbonate (PCTE) Membrane Filters, 0.2 Micron, 47mm, 100/Pk 0.2 47 100 1-2 days
$158.45
PCT029030 Polycarbonate (PCTE) Membrane Filters, 0.2 Micron, 90mm, 30/Pk 0.2 90 30 1-2 days
$93.30
PCT027630 Polycarbonate (PCTE) Membrane Filters, 0.2 Micron, 76mm, 30/Pk 0.2 76 30 1-2 days
$93.30
PCT0214220 Polycarbonate (PCTE) Membrane Filters, 0.2 Micron, 142mm, 20/Pk 0.2 142 20 1-2 days
$168.80
PCT0229320 Polycarbonate (PCTE) Membrane Filters, 0.2 Micron, 293mm, 20/Pk 0.2 293 20 1-2 days
$708.93
PCT0220030 Polycarbonate (PCTE) Membrane Filters, 0.2 Micron, 200 x 250mm, 30/Pk 0.2 200 x 250 30 1-2 days
$503.44
PCT023001 Polycarbonate (PCTE) Membrane Filters, 0.2 Micron, 300 x 3000mm, 1/Pk 0.2 300 x 3000 1 1-2 days
$441.23
PCT0413100 Polycarbonate (PCTE) Membrane Filters, 0.4 Micron, 13mm, 100/Pk 0.4 13 100 1-2 days
$85.90
PCT0425100 Polycarbonate (PCTE) Membrane Filters, 0.4 Micron, 25mm, 100/Pk 0.4 25 100 1-2 days
$96.24
PCT0437100 Polycarbonate (PCTE) Membrane Filters, 0.4 Micron, 37mm, 100/Pk 0.4 37 100 1-2 days
$125.88
PCT0137100 Polycarbonate (PCTE) Membrane Filters, 0.1 Micron, 37mm, 100/Pk 0.1 37 100 1-2 days
$125.88
PCT0447100 Polycarbonate (PCTE) Membrane Filters, 0.4 Micron, 47mm, 100/Pk 0.4 47 100 1-2 days
$158.45
PCT049030 Polycarbonate (PCTE) Membrane Filters, 0.4 Micron, 90mm, 30/Pk 0.4 90 30 1-2 days
$93.30
PCT0414220 Polycarbonate (PCTE) Membrane Filters, 0.4 Micron, 142mm, 20/Pk 0.4 142 20 1-2 days
$168.80
PCT0429320 Polycarbonate (PCTE) Membrane Filters, 0.4 Micron, 293mm, 20/Pk 0.4 293 20 1-2 days
$708.93
PCT0420030 Polycarbonate (PCTE) Membrane Filters, 0.4 Micron, 200 x 250mm, 30/pk 0.4 200 x 250 30 1-2 days
$503.44
PCT043001 Polycarbonate (PCTE) Membrane Filters, 0.4 Micron, 300 x 3000mm, 1/Pk 0.4 300 x 3000 1 1-2 days
$441.23
PCT0613100 Polycarbonate (PCTE) Membrane Filters, 0.6 Micron, 13mm, 100/Pk 0.6 13 100 1-2 days
$96.24
PCT0625100 Polycarbonate (PCTE) Membrane Filters, 0.6 Micron, 25mm, 100/Pk 0.6 25 100 1-2 days
$114.02
PCT0647100 Polycarbonate (PCTE) Membrane Filters, 0.6 Micron, 47mm, 100/Pk 0.6 47 100 1-2 days
$170.28
PCT067630 Polycarbonate (PCTE) Membrane Filters, 0.6 Micron, 76mm, 30/Pk 0.6 76 30 1-2 days
$96.24
PCT069030 Polycarbonate (PCTE) Membrane Filters, 0.6 Micron, 90mm, 30/Pk 0.6 90 30 1-2 days
$96.24
PCT0614220 Polycarbonate (PCTE) Membrane Filters, 0.6 Micron, 142mm, 20/Pk 0.6 142 20 1-2 days
$168.80
PCT0629320 Polycarbonate (PCTE) Membrane Filters, 0.6 Micron, 293mm, 20/Pk 0.6 293 20 1-2 days
$380.53
PCT0620030 Polycarbonate (PCTE) Membrane Filters, 0.6 Micron, 200 x 250mm, 30/Pk 0.6 200 x 250 30 1-2 days
$503.43
PCT0813100 Polycarbonate (PCTE) Membrane Filters, 0.8 Micron, 13mm, 100/Pk 0.8 13 100 1-2 days
$96.24
PCT0825100 Polycarbonate (PCTE) Membrane Filters, 0.8 Micron, 25mm, 100/Pk 0.8 25 100 1-2 days
$114.02
PCT0837100 Polycarbonate (PCTE) Membrane Filters, 0.8 Micron, 37mm, 100/Pk 0.8 37 100 1-2 days
$152.53
PCT0847100 Polycarbonate (PCTE) Membrane Filters, 0.8 Micron, 47mm, 100/Pk 0.8 47 100 1-2 days
$170.28
PCT089030 Polycarbonate (PCTE) Membrane Filters, 0.8 Micron, 90mm, 30/Pk 0.8 90 30 1-2 days
$134.74
PCT0814220 Polycarbonate (PCTE) Membrane Filters, 0.8 Micron, 142mm, 20/Pk 0.8 142 20 1-2 days
$168.80
PCT0820030 Polycarbonate (PCTE) Membrane Filters, 0.8 Micron, 200 x 250mm, 30/Pk 0.8 200 x 250 30 1-2 days
$503.44
PCT1013100 Polycarbonate (PCTE) Membrane Filters, 1.0 Micron, 13mm, 100/Pk 1 13 100 1-2 days
$96.24
PCT1025100 Polycarbonate (PCTE) Membrane Filters, 1.0 Micron, 25mm, 100/Pk 1 25 100 1-2 days
$114.02
PCT1047100 Polycarbonate (PCTE) Membrane Filters, 1.0 Micron, 47mm, 100/Pk 1 47 100 1-2 days
$170.28
PCT109030 Polycarbonate (PCTE) Membrane Filters, 1.0 Micron, 90mm, 30/Pk 1 90 30 1-2 days
$134.74
PCT1014220 Polycarbonate (PCTE) Membrane Filters, 1.0 Micron, 142mm, 20/Pk 1 142 20 1-2 days
$168.80
PCT1029320 Polycarbonate (PCTE) Membrane Filters, 1.0 Micron, 293mm, 20/Pk 1 293 20 1-2 days
$708.93
PCT1020030 Polycarbonate (PCTE) Membrane Filters, 1.0 Micron, 200 x 250mm, 30/Pk 1 200 x 250 30 1-2 days
$503.44
PCT2013100 Polycarbonate (PCTE) Membrane Filters, 2.0 Micron, 13mm, 100/Pk 2 13 100 1-2 days
$96.24
PCT2025100 Polycarbonate (PCTE) Membrane Filters, 2.0 Micron, 25mm, 100/Pk 2 25 100 1-2 days
$114.02
PCT2047100 Polycarbonate (PCTE) Membrane Filters, 2.0 Micron, 47mm, 100/Pk 2 47 100 1-2 days
$170.28
PCT209030 Polycarbonate (PCTE) Membrane Filters, 2.0 Micron, 90mm, 30/Pk 2 90 30 1-2 days
$134.74
PCT2014220 Polycarbonate (PCTE) Membrane Filters, 2.0 Micron, 142mm, 20/Pk 2 142 20 1-2 days
$168.80
PCT2029320 Polycarbonate (PCTE) Membrane Filters, 2.0 Micron, 293mm, 20/Pk 2 293 20 1-2 days
$380.54
PCT2020030 Polycarbonate (PCTE) Membrane Filters, 2.0 Micron, 200 x 250mm, 30/Pk 2 200 x 250 30 1-2 days
$547.85
PCT3013100 Polycarbonate (PCTE) Membrane Filters, 3.0 Micron, 13mm, 100/Pk 3 13 100 1-2 days
$96.24
PCT3025100 Polycarbonate (PCTE) Membrane Filters, 3.0 Micron, 25mm, 100/Pk 3 25 100 1-2 days
$111.07
PCT3047100 Polycarbonate (PCTE) Membrane Filters, 3.0 Micron, 47mm, 100/Pk 3 47 100 1-2 days
$170.28
PCT309030 Polycarbonate (PCTE) Membrane Filters, 3.0 Micron, 90mm, 30/Pk 3 90 30 1-2 days
$134.74
PCT3014220 Polycarbonate (PCTE) Membrane Filters, 3.0 Micron, 142mm, 20/Pk 3 142 20 1-2 days
$144.15
PCT3029320 Polycarbonate (PCTE) Membrane Filters, 3.0 Micron, 293mm, 20/Pk 3 293 20 1-2 days
$380.54
PCT3020030 Polycarbonate (PCTE) Membrane Filters, 3.0 Micron, 200 x 250mm, 30/Pk 3 200 x 250 30 1-2 days
$527.12
PCT5013100 Polycarbonate (PCTE) Membrane Filters, 5.0 Micron, 13mm, 100/Pk 5 13 100 1-2 days
$96.24
PCT5025100 Polycarbonate (PCTE) Membrane Filters, 5.0 Micron, 25mm, 100/Pk 5 25 100 1-2 days
$114.02
PCT5047100 Polycarbonate (PCTE) Membrane Filters, 5.0 Micron, 47mm, 100/Pk 5 47 100 1-2 days
$170.28
PCT509030 Polycarbonate (PCTE) Membrane Filters, 5.0 Micron, 90mm, 30/Pk 5 90 30 1-2 days
$121.72
PCT5014220 Polycarbonate (PCTE) Membrane Filters, 5.0 Micron, 142mm, 20/Pk 5 142 20 1-2 days
$168.80
PCT5029320 Polycarbonate (PCTE) Membrane Filters, 5.0 Micron, 293mm, 20/Pk 5 293 20 1-2 days
$416.59
PCT501942100 Polycarbonate (PCTE) Membrane Filters, 5.0 Micron, 19 x 42mm, 100/Pk 5 19 x 42 100 1-2 days
$125.88
PCT50258050 Polycarbonate (PCTE) Membrane Filters, 5.0 Micron, 25 x 80mm, 50/Pk 5 25 x 80 50 1-2 days
$88.86
PCT5020030 Polycarbonate (PCTE) Membrane Filters, 5.0 Micron, 200 x 250mm, 30/Pk 5 200 x 250 30 1-2 days
$547.85
PCT8013100 Polycarbonate (PCTE) Membrane Filters, 8.0 Micron, 13mm, 100/Pk 8 13 100 1-2 days
$96.24
PCT8025100 Polycarbonate (PCTE) Membrane Filters, 8.0 Micron, 25mm, 100/Pk 8 25 100 1-2 days
$114.02
PCT8047100 Polycarbonate (PCTE) Membrane Filters, 8.0 Micron, 47mm, 100/Pk 8 47 100 1-2 days
$170.28
PCT809030 Polycarbonate (PCTE) Membrane Filters, 8.0 Micron, 90mm, 30/Pk 8 90 30 1-2 days
$126.50
PCT8029320 Polycarbonate (PCTE) Membrane Filters, 8.0 Micron, 293mm, 20/PK 8 293 20 1-2 days
$364.27
PCT801942100 Polycarbonate (PCTE) Membrane Filters, 8.0 Micron, 19 x 42mm, 100/Pk 8 19 x 42 100 1-2 days
$114.41
PCT8020030 Polycarbonate (PCTE) Membrane Filters, 8.0 Micron, 200 x 250mm, 30/Pk 8 200 x 250 30 1-2 days
$503.44
PCT10013100 Polycarbonate (PCTE) Membrane Filters, 10.0 Micron, 13mm, 100/Pk 10 13 100 1-2 days
$96.24
PCT10025100 Polycarbonate (PCTE) Membrane Filters, 10.0 Micron, 25mm, 100/Pk 10 25 100 1-2 days
$119.95
PCT10047100 Polycarbonate (PCTE) Membrane Filters, 10.0 Micron, 47mm, 100/pk 10 47 100 1-2 days
$170.28
PCT1009030 Polycarbonate (PCTE) Membrane Filters, 10.0 Micron, 90mm, 30/pk 10 90 30 1-2 days
$134.74
PCT10014220 Polycarbonate (PCTE) Membrane Filters, 10.0 Micron, 142mm, 20/Pk 10 142 20 1-2 days
$164.36
PCT10020030 Polycarbonate (PCTE) Membrane Filters, 10.0 Micron, 200 x 250mm, 30/Pk 10 200 x 250 30 1-2 days
$503.43
1270166 Polycarbonate (PCTE) Membrane Filters, 12.0 Micron, 13mm, 100/Pk 12 13 100 1-2 days
$96.24
1270167 Polycarbonate (PCTE) Membrane Filters, 12.0 Micron, 25mm, 100/Pk 12 25 100 1-2 days
$114.02
1270169 Polycarbonate (PCTE) Membrane Filters, 12.0 Micron, 47mm, 100/Pk 12 47 100 1-2 days
$170.28
1270170 Polycarbonate (PCTE) Membrane Filters, 12.0 Micron, 200 x 250mm, 30/Pk 12 200 x 250 30 1-2 days
$521.78
1270168 Polycarbonate (PCTE) Membrane Filters, 12.0 Micron, 300 x 3000mm, 1/Pk 12 300 x 3000 1 1-2 days
$441.23
PCT14013100 Polycarbonate (PCTE) Membrane Filters, 14.0 Micron, 13mm, 100/Pk 14 13 100 1-2 days
$96.24
PCT14025100 Polycarbonate (PCTE) Membrane Filters, 14.0 Micron, 25mm, 100/Pk 14 25 100 1-2 days
$114.02
PCT14047100 Polycarbonate (PCTE) Membrane Filters, 14.0 Micron, 47mm, 100/Pk 14 47 100 1-2 days
$170.28
PCT1409030 Polycarbonate (PCTE) Membrane Filters, 14.0 Micron, 90mm, 30/Pk 14 90 30 1-2 days
$102.72
1270172 Polycarbonate (PCTE) Membrane Filters, 20.0 Micron, 13mm, 100/Pk 20 13 100 1-2 days
$192.47
1270174 Polycarbonate (PCTE) Membrane Filters, 20.0 Micron, 25mm, 100/Pk 20 25 100 1-2 days
$228.03
1270175 Polycarbonate (PCTE) Membrane Filters, 20.0 Micron, 47mm, 100/Pk 20 47 100 1-2 days
$340.54
1270176 Polycarbonate (PCTE) Membrane Filters, 20.0 Micron, 90mm, 30/Pk 20 90 30 1-2 days
$304.25
PCT25013100 Polycarbonate (PCTE) Membrane Filters, 25.0 Micron, 13mm, 100/Pk 25 13 100 1-2 days
$283.46
PCT25025100 Polycarbonate (PCTE) Membrane Filters, 25.0 Micron, 25mm, 100/Pk 25 25 100 1-2 days
$223.97
PCT25047100 Polycarbonate (PCTE) Membrane Filters, 25.0 Micron, 47mm, 100/Pk 25 47 100 1-2 days
$353.12
PCT2509030 Polycarbonate (PCTE) Membrane Filters, 25.0 Micron, 90mm, 30/Pk 25 90 30 1-2 days
$353.12
PCT25020030 Polycarbonate (PCTE) Membrane Filters, 25.0 Micron, 200 x 250mm, 30/Pk 25 200 x 250 30 1-2 days
$3,587.89
PCT30013100 Polycarbonate (PCTE) Membrane Filters, 30.0 Micron, 13mm, 100/Pk 30 13 100 1-2 days
$216.58
PCT30025100 Polycarbonate (PCTE) Membrane Filters, 30.0 Micron, 25mm, 100/Pk 30 25 100 1-2 days
$245.30
PCT30047100 Polycarbonate (PCTE) Membrane Filters, 30.0 Micron, 47mm, 100/Pk 30 47 100 1-2 days
$386.74
PCT3009030 Polycarbonate (PCTE) Membrane Filters, 30.0 Micron, 90mm, 30/Pk 30 90 30 1-2 days
$541.41
PCT30020030 Polycarbonate (PCTE) Membrane Filters, 1E4 Density, 30.0 Micron, 200 x 250mm, 30/Pk 30 200 x 250 30 1-2 days
$3,587.89
1270018 Polycarbonate (PCTE) Membrane Filters, 0.4 Micron, 19.05mm, 100/Pk 0.4 19.05 100 1-2 days
$96.24
1270090 Polycarbonate (PCTE) Membrane Filters, 0.03 Micron, 19.05mm, 100/Pk 0.03 19.05 100 1-2 days
$178.28
PCT00162X22100 Polycarbonate (PCTE) Membrane Filters, 0.01 Micron, 62 x 22mm, 100/Pk 0.01 62 x 22 100 1-2 days
$397.95
1270091 Polycarbonate (PCTE) Membrane Filters, 0.08 Micron, 19.05mm, 100/Pk 0.08 19.05 100 1-2 days
$178.28
1270092 Polycarbonate (PCTE) Membrane Filters, 1.0 Micron, 19.05mm, 100/Pk 1 19.05 100 1-2 days
$110.69
1270193 Polycarbonate (PCTE) Membrane Filters, 0.1 Micron, 19.05mm, 100/Pk 0.1 19.05 100 1-2 days
$146.30
1270209 Polycarbonate (PCTE) Membrane Filters, 20.0 Micron, 142mm, 20/Pk 20 142 20 1-2 days
$373.15
PCT0019030 Polycarbonate (PCTE) Membrane Filters, 0.01 Micron, 90mm, 30/pk 0.01 90 30 1-2 days
$201.78
PCT503001 Polycarbonate (PCTE) Membrane Filters, 5.0 Micron, 300 x 3000mm, 1/Pk 5 300 x 3000 1 1-2 days
$441.22
PCT803001 Polycarbonate (PCTE) Membrane Filters, 8.0 Micron, 300 x 3000mm, 1/Pk 8 300 x 3000 1 1-2 days
$414.59
1270015 Polycarbonate (PCTE) Membrane Filters, 0.05 Micron, 19.05mm, 100/Pk 0.05 19.05 100 1-2 days
$178.28
1270017 Polycarbonate (PCTE) Membrane Filters, 0.2 Micron, 19.05mm, 100/Pk 0.2 19.05 100 1-2 days
$96.24
1270019 Polycarbonate (PCTE) Membrane Filters, 0.8 Micron, 19.05mm, 100/Pk 0.8 19.05 100 1-2 days
$114.02
per page
Set Descending Direction

Frequently Asked Questions

The pores of microporous membrane filters act as small capillaries.  When hydrophilic membranes come into contact with water, capillary action associated with surface tension forces causes the water to spontaneously enter and fill the pores.  In this manner, the membranes are easily wetted and allow the bulk flow of water through the pores.  Once wetted, hydrophilic membranes will not allow the bulk flow of air or other gasses, unless they are applied at pressures greater than the membrane’s bubble point.

Hydrophilic membrane filters are typically used with water and aqueous solutions.  They can also be used with compatible non-aqueous fluids.  Hydrophilic membrane filters are typically not used for air, gas or vent filtration since the filters would block flow if inadvertently wetted, by condensation for example.

When hydrophobic membranes come into contact with water, surface tension forces act to repel the water from the pores.  Water will not enter the pores and the membranes will act as a barrier to water flow, unless the water is applied at pressures greater than the membrane’s water entry pressure.  Low surface tension fluids, such as alcohols, can spontaneously enter and fill the pores of hydrophobic membranes.  Once all the air in the pores is displaced, there are no longer any surface tension forces and water can easily enter the pores, displace the low surface tension fluid, and pass through the membrane.  The membrane will then allow bulk flow of water for as long as the pore remain water filled.  If the membrane is allowed to dry (i.e. air enters the pores), then it must be pre-wet with a low surface tension fluid again prior to use with water.

Hydrophobic membrane filters are typically used with compatible non-aqueous fluids.  They are also commonly used as air, gas, or vent filters.  Hydrophobic membrane filters are sometimes used with water or aqueous solutions; and, in these applications, they must first be prewet with a low surface tension, water miscible fluid prior to use.

Polycarbonate (PC) and Polyester (PET) track-etch membrane filters are precision, two-dimensional microporous “screen” membranes with straight-through, cylindrical pores created by the track-etching process. Because the pore structure is uniform and non-tortuous, particles are captured primarily on the membrane surface, providing a highly accurate and reproducible separation cut-off compared to depth filter media.

Track-etch membranes are known for having some of the most precise pore size distributions of any membrane filter, making them ideal for applications that require exact particle sizing and surface capture, such as microscopy, particle analysis, microbial enumeration, and sample preparation.

These membranes are also very thin (typically ~6–15 µm) yet surprisingly durable, and can withstand high differential pressures (over 3,000 psi when properly supported). They are available in a range of appearances, from opaque to nearly transparent, including black options for enhanced contrast in imaging and microscopy.

Sterlitech Polycarbonate (PCTE) and Polyester (PETE) track-etched filter membranes offer ultra-low non-specific binding and a smooth, flat surface that captures particles on a single plane—ideal for microscopy, SEM, and particle analysis. Manufactured under Class 100 cleanroom conditions, they are contaminant- and pyrogen-free, with very low extractables and no fiber shedding. Both membranes are biologically inert, provide precise, uniform pore sizes, and deliver excellent chemical and thermal stability, with PETE offering higher solvent resistance.

Sterlitech Track-Etched Polycarbonate membranes are not recommended for venting applications. PVP-free polycarbonate membranes have a water contact angle of ~90° and can wet out under low differential pressure, allowing liquid to pass through. As a result, they do not effectively retain liquids while venting gases. For vent filter applications where gas permeability and liquid blocking are required, Sterlitech recommends hydrophobic PTFE, hydrophobic polyethylene, or oleophobic polyester membranes, which provide higher water entry pressure and allow gases and water vapor to pass while preventing liquid breakthrough.

Polycarbonate track-etch (PCTE) membranes are inherently
hydrophobic.  The hydrophobic PCTE
membrane filters shown at https://www.sterlitech.com/hydrophobic-polycarbonate-membrane-filters.html do not have any wetting agents.  Before use in water or aqueous solutions, these filters are usually pre-wet with a compatible low surface tension, water miscible fluid such as a low molecular weight alcohol. 

The hydrophilic PCTE membrane filters shown at https://www.sterlitech.com/hydrophilic-polycarbonate-membrane-filters.html are treated with a wetting agent to render the membrane hydrophilic.  The wetting agent consists of a few molecular
thicknesses of polyvinylpyrrolidone (PVP) deposited on the membrane
surfaces.  The hydrophilic PCTE membrane filters can be used in water or aqueous solutions without pre-wetting.

Q. Can Polycarbonate membrane be bonded with adhesives?

A. Polycarbonate membranes can be adhesive bonded to each other or to other plastics, metals, glass or wood using commercially available one component, two component and pressure adhesives.

Depending on the cell line, most exfoliated human cells adhere with some tenacity. Most epithelial cells will adhere if the membrane has a negative charge applied by gas plasma or has a suitable attractant applied to the surface of the membrane. Endothelial cells will generally not attach to the surface of Track Etch membranes.

There is a visually apparent difference between the sides of some of the PCTE membrane filters.  This is a result of the process used to manufacture the polycarbonate base film.  One side of the film has a very smooth surface resulting in a shiny appearance.  The other side has an inherent surface texture resulting in a dull or matte appearance.  The difference is purely physical; both sides are chemically the same.  Filter orientation does not affect particle retention.  For applications involving microscopic analyses of captured particles or microbes, most users prefer to orient the disk filter so that the smooth shiny side is facing upstream.

Q. I am looking for a black polycarbonate membrane pore size that is not listed. Can I dye the standard polycarbonate membrane? How do I do this?

A. Yes, but we usually recommend the PVP-free polycarbonate membranes. Note that black polycarbonate membranes are used for counting particulates and performing fluorescent microscopy.

If you need to create a black membrane that is not listed on this site, the standard method for rendering polycarbonate membranes black in a lab follows:

Dissolve 2 gm of Irgalan black (Chemical Index, acid black 107) in 1 liter of 2% acetic acid.
Soak membranes in Irgalan black solution for 24 hours.
Rinse with water, air dry.
To obtain a darker black, dry at 180ºF (82ºC) for 15 minutes.

**Note: There have been instances of Irgalan Black "bleeding" off of the membrane.   This is not common, but has occurred.

Q. Why offer both polyester and polycarbonate track-etch filter membranes?

A. The greatest advantage of using polyester is that it has better solvent resistance and it is prone to fewer wrinkles in the manufacturing process. One of the main reasons polycarbonate was originally used and continues to be used by most people is that for over 30 years the end-users have known mainly polycarbonate.

Polycarbonate works better with live or fixed cells than does polyester. However, both polycarbonate  and polyester offer very high quality end product that is suitable for a large variety of applications.

Q. I am having a problem when I force liquids under pressure through a membrane with a very small pore size. Little or no liquid is seen to pass through the membrane, what could be the problem?

A. There could be a number of things going on to restrict the flow through the membrane.

First you want to take the original flow rate into consideration, for example a 25mm polycarbonate membrane with a 0.05 micron pore size and a flow rate of 0.4ml/min/cm2 is only going to get about 1.2 mil of liquid through a minute. This amount decreases with smaller pore sizes.

Another thing to consider is if the liquid is being properly prefiltered. With such small pore sizes, 0.05-0.01micron, you need to filter in a step down manner so as not to plug the pores. Step down means a series of filters with decreasing pore size.

This should eliminate most problems with flow through the membrane; other issues need to be evaluated on an individual basis.

Q. I just received a box of Sterlitech Track-Etch filter membranes and I am trying to use them, but there is no liquid passing through. What is wrong?

A. Believe it or not, in most cases end-users tend to use the blue separator paper instead of the membrane because the separator paper has the physical qualities that make it look more like a typical depth filter than the Track-Etch filter membrane.

Always remember that the filter membrane is usually opaque or translucent and is generally white or white with a yellow or green tint to it. The separator paper is usually blue or imprinted and should not be used for filtration.

Another reason for lack of filtration is due to particle loading on the membrane that would cause the filter to plug. Because Sterlitech Track-Etch filter membranes are made of plastic with cylindrical pores, they capture 100% of all particles larger than the pore size. Therefore, they have a higher incidence of plugging due to their high level of capturability. It is highly recommended that unless the end-user is capturing particles on the surface for analysis that a glass fiber prefilter is used on top of the track-etch membrane. The glass fiber prefilter will capture most of the larger particulate, thereby keeping it from loading up on the surface of the membrane and plugging it.

The use of a mesh spacer (drain disks) is also helpful for maximizing flow. A mesh spacer is set under the membrane and on top of the filter holder. The mesh spacer lifts the membrane off the mostly solid filter holder surface, allowing increased filtration by allowing tangential flow to occur. This is particularly applicable with stainless steel supports.

Q. We would like a higher density Polycarbonate membrane (PCTE). Is it available?

A. Yes, custom density PCTE is available.   Please contact our sales team for a quote ([email protected])

Q. What are the advantatges of Sterlitech polycarbonate and polyester membrane filters?

A. Yes, the polycarbonate track-etch (PCTE) membrane filters have good biocompatibility and pass USP Class VI testing. The PCTE membrane filters are neither cytotoxic nor bactericidal. Cells and bacteria will grow on the filters when proper nutrients are supplied and proper conditions are maintained.

Q. What membrane works best for cell studies?

A. Sterlitech Polycarbonate (PCTE) and Polyester (PETE) membranes are ideal for cell studies. They are neither cytotoxic nor bactericidal. Cells will grow on the membranes if provided with a nutrient.

The membranes can be repeatedly autoclaved at 121°C (250°F), and no damage has been observed in membranes with a sustained exposure to temperatures of 140°C (284°F) in air or steam.

PCTE membranes are neutral biologically, being neither cytotoxic nor bactericidal. Cells and bacteria will grow on PCTE membranes when proper nutrients are supplied. PCTE membranes pass all USP Class VI tests for bio-compatibility and are completely safe to use in implant studies.

Randomly selected samples of polycarbonate and polyester track-etched membranes were tested by an independent laboratory with MEM Extract/L929 Mouse Fibroblast Cells. No evidence of cytotoxic response was noted during a seventy-two (72) hour exposure period, and the materials were judged to be negatively cytotoxic.

Q. Is there any way I can get rid of the pores on Sterlitech's Track-Etch filter membranes?

A. If you want to completely get rid of the pores, the easiest way to do so is to dissolve the filter away using chloroform or touch prep.

Q. How do I remove the PVP hydrophilic coating from the surfaces of a polycarbonate membrane filter?

A.  Sterlitech’s polycarbonate membranes are naturally hydrophobic but are coated with PVP to produce a hydrophilic version. While the full range of pores sizes (0.01um-30.0um) are available as hydrophilic filters, we are only able to offer a limited number of pore sizes (0.1um-10.0um) as hydrophobic (PVP-Free).

Fortunately, the PVP can be removed without much hassle.  Boil the membrane(s) for at least 1 hour in deionized ultra-pure water, remove, then air dry the membrane(s).  Once the membrane dries it will be hydrophobic and PVP-Free.

Q. Why are black polycarbonate membranes better than other membranes for counting bacteria?

A. Black polycarbonate membranes are better than cellulose membranes for the direct counting of bacteria, because they have a uniform pore size and a flat surface that retains all of the bacteria on top of the filter. Although cellulose filters also retain all of the bacteria, many become trapped inside the filter where they cannot be counted.

Yes, in some cases within manufacturing capabilities, Sterlitech can provide track-etch membrane filters with non-standard custom specifications for pore diameter, pore density, membrane thickness, and surface treatments.  Please contact us at [email protected] to discuss your application and to inquire about availability.

Thickness, Bubble Point, Pore Size, and Pore Density remain unchanged when stored at a temperature from +5 to 35°C and a humidity of 20 to 80 % for up to 8 years

Q: Why are black dyed polycarbonate track-etch (PCTE) membrane filters preferred for use in epiflourescence microscopy?

A: Black dyed PCTE membrane filters provide the same advantages as regular PCTE membrane filters for microscopy applications, but also have exceptionally low autoflourescence. This permits high contrast between flourescent stained microorganisms and the dark surface of the membrane filters.  The very low autoflourescence of the black dyed PCTE membrane filters also makes them suitable for applications that use automated detection of flourescently labeled microorganisms such as laser scanning cytometry.

Q: Do polycarbonate track-etch (PCTE) membrane filters contain Bisphenol-A (BPA)?

A: Bisphenol-A (BPA) is the monomer used to manufacture polycarbonate. It is not expected that the polycarbonate track-etch (PCTE) membrane filters would contain significant residual amounts of BPA. However, the filters are not analyzed on a lot basis for residual BPA so they cannot be described as BPA free. The user is advised that extreme application conditions, including exposure to high temperatures and/or exposure to incompatible fluids, may attack the molecular structure of the polycarbonate and release trace amounts of BPA. For applications where trace amounts of BPA may cause concern, polyester track-etch (PETE) membrane filters may be considered.

The polycarbonate track-etch (PCTE) membrane filters are quite thin and translucent.  Depending on pore size rating and pore density, the filters may appear transparent or may appear opaque.  Please review https://www.sterlitech.com/blog/post/clarifying-the-matter-of-polycarbonates-membrane-clarity.  In some instances, when PCTE membrane filters with standard specifications appear opaque, Sterlitech can provide custom low pore density filters with the same pore size rating that are transparent.  For comparison, most conventional microporous membrane filters are considerably thicker and cannot be made transparent.  Please contact us at [email protected] to discuss your application and to inquire about the availability custom PCTE membrane filters.

When performing microscopic studies of particles or cells resting on the surface of PCTE membrane filters, some users may find the appearance of the pore edges to be a hindrance.  There are some strategies that can be employed to reduce the appearance of the pore edges.  One of the simplest strategies is to dissolve the membrane, with chloroform or toluene for examples, leaving behind the particles.  Additionally, using a combination of wetting the membrane with a liquid that has the correct refractive index and illuminating the membrane with polarized light, it is possible to make the pores invisible.  The PCTE membrane is birefringent and has two refractive indices, 1.584 and 1.625.  To make the pores invisible, the membrane is wetted with a fluid that has a refractive index of 1.584 and is illuminated with properly oriented polarized light.

The polycarbonate track-etch (PCTE) membrane filters can be dissolved with dipolar aprotic solvents such as dimethylformamide (DMF), dimethyl sulfoxide (DMSO) and n-methyl-2-pyrrolidone (NMP).  The PCTE membrane filters can also be dissolved with the organic chlorinated solvents dichloromethane (DCM or methylene chloride) and trichloromethane (TCM or chloroform).  PCTE membrane filters can also be dissolved with toluene and potentially with other similar aromatic hydrocarbon solvents.

The polyester track-etch (PETE) membrane filters can be dissolved with m-Cresol, o-Chlorophenol, hexafluoroisopropanol, and trifluoroacetic acid (TFA).

Both types of track-etch membranes can be dissolved with elevated temperature sodium hydroxide solutions.

Membranes are used in the study of white blood cell reactions to toxins (chemotaxis), to determine the natural immunity in whole blood. Since immunity is transferable, this could lead to the development of vaccines for treatment of cancer and other diseases. Membranes may be polycarbonate, with or without polyvinylpyrrolidone (PVP). It depends on the type of cells used. Apparently, Neutrophils have a tendency to round up and fall off the membrane when around PVP - not so with some of the other types of cells. Refer to each procedure. Characteristics of PCTE Membrane and Advantages in Chemotaxis Studies Uniform Properties yield reliable, consistent, and reproducible results. Less cell distortion for improved morphology.
Zero leaching of offensive surfactants yields reliable, consistent, and reproducible results.
Smooth, flat surface contributes to high cell visibility on proximal and distal surfaces. Improved morphologic resolution. Easy removal of excess cells from proximal surface.
Thinness of the membrane allows shorter incubation time. More assays made faster and simpler. Chamber sterilization not needed for most studies. Facilitates study of slower moving cells (e.g., monocytes and macrophages).
Low adsorption and absorption of cells causes higher yields. Enhanced radiometric analysis.
Non-staining results in improved contrast. Simplifies optical microscopic analysis routine.
Transparency simplifies optical microscopic analysis routine.
Heat sealable characteristics aids in experimenting with disposable chambers.
Strength of membrane means that less critical handling techniques needed.
Coating Membranes with Gelatin Wash membrane with 0.5% Acetic Acid.
Make a stock gelatin solution with 50mg/10mL water.
Working solution is 1-mL stock to 1-liter water for a light coating.
Then the membranes are placed in a rolling boil of this solution in a beaker for 1 hour.
The membranes are individually pulled out and placed on filter paper to air dry. If an oven is used, use very low temperature for 20 minutes. Air-drying is best in a covered dish left over night. Keep clean.
When the membranes are dry, place them back in their original box.
NOTE: For Chemotaxis, the most important issue is to keep everything at 37 degrees C., the water bath, buffers, glassware, etc. for 1 hour. Studies in cold produce cells that "round up", curl up and fall off. 

We have a Chemical Compatibility Chart that you can use for reference. 

Nominal pore size ratings provide a general indication of filter retention efficiency, meaning some particles equal to or larger than the stated pore size may pass through the filter. Nominal ratings can vary by manufacturer, so filters with the same nominal pore size may not offer equivalent filtration performance.

Absolute pore size ratings are determined through controlled particle or microbial retention testing and represent the smallest particles that are consistently retained by the membrane. These ratings are often correlated with bubble point specifications and are generally more comparable across manufacturers.

Important: Actual filtration performance depends on application conditions, even when using filters with absolute pore size ratings.

The pore size refers to the diameter of the individual pores in a membrane filter.   Pore size is typically specified in micrometers (µm).   Most membranes and filter media actually contain a distribution of pore sizes.  Nominal pore size ratings typically refer to the predominant pore size of a filtration media; pores larger and smaller than the nominal rating may be present.  Absolute pore size ratings typically refer to the largest pore size of a membrane and it is expected that all pores will be equal to or smaller than the absolute rating.

For the polycarbonate track-etch (PCTE) and polyester track-etch (PETE) membrane filters, porosity is the percent of the total surface area occupied by the pores; it typically ranges from <1% to 16%.  For the other membrane filters, porosity is the percent of the total volume occupied by the pores; it typically ranges from 40 to 80%.

You can find the Sterlitech compatibility guide.  It is important to realize that application conditions, such as operating temperature, affect compatibility.  Please contact us at [email protected] if you need assistance.

A. We have several membranes to recommend for gravimetric analysis.

  • Mixed Cellulose Esters (MCE) Membrane Filters, Plain: In gravimetric analysis using ashing techniques, (MCE) Nitrocellulose filters yield a residue of less than 0.045% of their initial weight.  They are hydrophilic with a non-cytotoxic wetting agent extractable level of less than 4% of their weight.
  • Polycarbonate Track-Etch Membranes (PCTE) - 25mm:  Polycarbonate Track-Etch or our Polyester Track-Etch (PETE) membranes are two membranes that offer exceptionally low tare weights, are non-hygroscopic, and exhibit extremely low absorption and adsorption losses.
    Since these membranes are non-hygroscopic, they are particularly well suited for gravimetric analysis.  They do not require drying when used directly out of the package.  If they are wet, they can be dried rapidly and will not pick up moisture from the air during weighing.
  • Glass Fiber Filters & Prefilters:  Glass fiber filters without binders are recommended for analytical and gravimetric determinations.

The bubble point is the minimum amount of pressure required to push air bubbles through the largest pore of a wet membrane.  The bubble point is inversely proportional to the pore diameter, as the pore diameter decreases the bubble point increases and vice versa.

Retention efficiency of membrane filters can be directly measured by challenging the filters with suspensions of standard microorganism cultures or particles of known size.  Unfortunately, such efficiency testing is necessarily destructive.  However, since retention characteristics are dependent on pore size, it is possible to correlate destructive challenge testing results to non-destructive membrane bubble point tests.  In this manner, the relationship between membrane pore size and membrane bubble point is empirically determined.  Typically, a minimum bubble point can be determined and specified for a particular pore size rating.  The bubble point specification is then used for quality control during membrane manufacture.  The bubble point can also be used by the consumer as a nondestructive test to verify membrane integrity before and/or after use.    

Depth filters are constructed with relatively thick filtration media and typically have nominal pore size ratings >1µm. Due to their large void volume, they capture significant amounts of particulate within their pore structure.
Membrane filters are typically composed of polymers that have been chemically processed, resulting in highly porous thin films with microscopic pore structures. Membrane filters typically have absolute pore size ratings <1µm, with some exceptions. Because of their very fine pore structure, membrane filters tend to trap the majority of particles on the surface. However, smaller particles with diameters near or below the pore size rating can be captured within the membrane or pass through the membrane.

Sample packs allow the customer to purchase small quantities of membrane filters at nominal cost, with various diameters and pore sizes as selected.  This allows the customer to preform trials as needed to determine the optimal filter for their application before committing to purchasing standard pack quantities.

 

In most cases, membrane filter samples can be purchased in sizes that are not listed in the standard sample packs.  Please contact us at [email protected] to inquire about availability and pricing.

membrane filters vs separator papers

To ensure ease of use, the membrane filters as stacked in their packaging are interleafed with layers of separator paper.  In most cases, the membrane filters will be white in color except for the track-etch membranes which are colorless and translucent.  In some special cases, the membranes will be dyed dark grey to black in appearance.  In all cases, the separator paper will be a different color than the membrane and is usually not white.  Please contact us at [email protected] if you need assistance.

Frequently Asked Questions

The pores of microporous membrane filters act as small capillaries.  When hydrophilic membranes come into contact with water, capillary action associated with surface tension forces causes the water to spontaneously enter and fill the pores.  In this manner, the membranes are easily wetted and allow the bulk flow of water through the pores.  Once wetted, hydrophilic membranes will not allow the bulk flow of air or other gasses, unless they are applied at pressures greater than the membrane’s bubble point.

Hydrophilic membrane filters are typically used with water and aqueous solutions.  They can also be used with compatible non-aqueous fluids.  Hydrophilic membrane filters are typically not used for air, gas or vent filtration since the filters would block flow if inadvertently wetted, by condensation for example.

When hydrophobic membranes come into contact with water, surface tension forces act to repel the water from the pores.  Water will not enter the pores and the membranes will act as a barrier to water flow, unless the water is applied at pressures greater than the membrane’s water entry pressure.  Low surface tension fluids, such as alcohols, can spontaneously enter and fill the pores of hydrophobic membranes.  Once all the air in the pores is displaced, there are no longer any surface tension forces and water can easily enter the pores, displace the low surface tension fluid, and pass through the membrane.  The membrane will then allow bulk flow of water for as long as the pore remain water filled.  If the membrane is allowed to dry (i.e. air enters the pores), then it must be pre-wet with a low surface tension fluid again prior to use with water.

Hydrophobic membrane filters are typically used with compatible non-aqueous fluids.  They are also commonly used as air, gas, or vent filters.  Hydrophobic membrane filters are sometimes used with water or aqueous solutions; and, in these applications, they must first be prewet with a low surface tension, water miscible fluid prior to use.

Polycarbonate (PC) and Polyester (PET) track-etch membrane filters are precision, two-dimensional microporous “screen” membranes with straight-through, cylindrical pores created by the track-etching process. Because the pore structure is uniform and non-tortuous, particles are captured primarily on the membrane surface, providing a highly accurate and reproducible separation cut-off compared to depth filter media.

Track-etch membranes are known for having some of the most precise pore size distributions of any membrane filter, making them ideal for applications that require exact particle sizing and surface capture, such as microscopy, particle analysis, microbial enumeration, and sample preparation.

These membranes are also very thin (typically ~6–15 µm) yet surprisingly durable, and can withstand high differential pressures (over 3,000 psi when properly supported). They are available in a range of appearances, from opaque to nearly transparent, including black options for enhanced contrast in imaging and microscopy.

Sterlitech Polycarbonate (PCTE) and Polyester (PETE) track-etched filter membranes offer ultra-low non-specific binding and a smooth, flat surface that captures particles on a single plane—ideal for microscopy, SEM, and particle analysis. Manufactured under Class 100 cleanroom conditions, they are contaminant- and pyrogen-free, with very low extractables and no fiber shedding. Both membranes are biologically inert, provide precise, uniform pore sizes, and deliver excellent chemical and thermal stability, with PETE offering higher solvent resistance.

Sterlitech Track-Etched Polycarbonate membranes are not recommended for venting applications. PVP-free polycarbonate membranes have a water contact angle of ~90° and can wet out under low differential pressure, allowing liquid to pass through. As a result, they do not effectively retain liquids while venting gases. For vent filter applications where gas permeability and liquid blocking are required, Sterlitech recommends hydrophobic PTFE, hydrophobic polyethylene, or oleophobic polyester membranes, which provide higher water entry pressure and allow gases and water vapor to pass while preventing liquid breakthrough.

Polycarbonate track-etch (PCTE) membranes are inherently
hydrophobic.  The hydrophobic PCTE
membrane filters shown at https://www.sterlitech.com/hydrophobic-polycarbonate-membrane-filters.html do not have any wetting agents.  Before use in water or aqueous solutions, these filters are usually pre-wet with a compatible low surface tension, water miscible fluid such as a low molecular weight alcohol. 

The hydrophilic PCTE membrane filters shown at https://www.sterlitech.com/hydrophilic-polycarbonate-membrane-filters.html are treated with a wetting agent to render the membrane hydrophilic.  The wetting agent consists of a few molecular
thicknesses of polyvinylpyrrolidone (PVP) deposited on the membrane
surfaces.  The hydrophilic PCTE membrane filters can be used in water or aqueous solutions without pre-wetting.

Q. Can Polycarbonate membrane be bonded with adhesives?

A. Polycarbonate membranes can be adhesive bonded to each other or to other plastics, metals, glass or wood using commercially available one component, two component and pressure adhesives.

Depending on the cell line, most exfoliated human cells adhere with some tenacity. Most epithelial cells will adhere if the membrane has a negative charge applied by gas plasma or has a suitable attractant applied to the surface of the membrane. Endothelial cells will generally not attach to the surface of Track Etch membranes.

There is a visually apparent difference between the sides of some of the PCTE membrane filters.  This is a result of the process used to manufacture the polycarbonate base film.  One side of the film has a very smooth surface resulting in a shiny appearance.  The other side has an inherent surface texture resulting in a dull or matte appearance.  The difference is purely physical; both sides are chemically the same.  Filter orientation does not affect particle retention.  For applications involving microscopic analyses of captured particles or microbes, most users prefer to orient the disk filter so that the smooth shiny side is facing upstream.

Q. I am looking for a black polycarbonate membrane pore size that is not listed. Can I dye the standard polycarbonate membrane? How do I do this?

A. Yes, but we usually recommend the PVP-free polycarbonate membranes. Note that black polycarbonate membranes are used for counting particulates and performing fluorescent microscopy.

If you need to create a black membrane that is not listed on this site, the standard method for rendering polycarbonate membranes black in a lab follows:

Dissolve 2 gm of Irgalan black (Chemical Index, acid black 107) in 1 liter of 2% acetic acid.
Soak membranes in Irgalan black solution for 24 hours.
Rinse with water, air dry.
To obtain a darker black, dry at 180ºF (82ºC) for 15 minutes.

**Note: There have been instances of Irgalan Black "bleeding" off of the membrane.   This is not common, but has occurred.

Q. Why offer both polyester and polycarbonate track-etch filter membranes?

A. The greatest advantage of using polyester is that it has better solvent resistance and it is prone to fewer wrinkles in the manufacturing process. One of the main reasons polycarbonate was originally used and continues to be used by most people is that for over 30 years the end-users have known mainly polycarbonate.

Polycarbonate works better with live or fixed cells than does polyester. However, both polycarbonate  and polyester offer very high quality end product that is suitable for a large variety of applications.

Q. I am having a problem when I force liquids under pressure through a membrane with a very small pore size. Little or no liquid is seen to pass through the membrane, what could be the problem?

A. There could be a number of things going on to restrict the flow through the membrane.

First you want to take the original flow rate into consideration, for example a 25mm polycarbonate membrane with a 0.05 micron pore size and a flow rate of 0.4ml/min/cm2 is only going to get about 1.2 mil of liquid through a minute. This amount decreases with smaller pore sizes.

Another thing to consider is if the liquid is being properly prefiltered. With such small pore sizes, 0.05-0.01micron, you need to filter in a step down manner so as not to plug the pores. Step down means a series of filters with decreasing pore size.

This should eliminate most problems with flow through the membrane; other issues need to be evaluated on an individual basis.

Q. I just received a box of Sterlitech Track-Etch filter membranes and I am trying to use them, but there is no liquid passing through. What is wrong?

A. Believe it or not, in most cases end-users tend to use the blue separator paper instead of the membrane because the separator paper has the physical qualities that make it look more like a typical depth filter than the Track-Etch filter membrane.

Always remember that the filter membrane is usually opaque or translucent and is generally white or white with a yellow or green tint to it. The separator paper is usually blue or imprinted and should not be used for filtration.

Another reason for lack of filtration is due to particle loading on the membrane that would cause the filter to plug. Because Sterlitech Track-Etch filter membranes are made of plastic with cylindrical pores, they capture 100% of all particles larger than the pore size. Therefore, they have a higher incidence of plugging due to their high level of capturability. It is highly recommended that unless the end-user is capturing particles on the surface for analysis that a glass fiber prefilter is used on top of the track-etch membrane. The glass fiber prefilter will capture most of the larger particulate, thereby keeping it from loading up on the surface of the membrane and plugging it.

The use of a mesh spacer (drain disks) is also helpful for maximizing flow. A mesh spacer is set under the membrane and on top of the filter holder. The mesh spacer lifts the membrane off the mostly solid filter holder surface, allowing increased filtration by allowing tangential flow to occur. This is particularly applicable with stainless steel supports.

Q. We would like a higher density Polycarbonate membrane (PCTE). Is it available?

A. Yes, custom density PCTE is available.   Please contact our sales team for a quote ([email protected])

Q. What are the advantatges of Sterlitech polycarbonate and polyester membrane filters?

A. Yes, the polycarbonate track-etch (PCTE) membrane filters have good biocompatibility and pass USP Class VI testing. The PCTE membrane filters are neither cytotoxic nor bactericidal. Cells and bacteria will grow on the filters when proper nutrients are supplied and proper conditions are maintained.

Q. What membrane works best for cell studies?

A. Sterlitech Polycarbonate (PCTE) and Polyester (PETE) membranes are ideal for cell studies. They are neither cytotoxic nor bactericidal. Cells will grow on the membranes if provided with a nutrient.

The membranes can be repeatedly autoclaved at 121°C (250°F), and no damage has been observed in membranes with a sustained exposure to temperatures of 140°C (284°F) in air or steam.

PCTE membranes are neutral biologically, being neither cytotoxic nor bactericidal. Cells and bacteria will grow on PCTE membranes when proper nutrients are supplied. PCTE membranes pass all USP Class VI tests for bio-compatibility and are completely safe to use in implant studies.

Randomly selected samples of polycarbonate and polyester track-etched membranes were tested by an independent laboratory with MEM Extract/L929 Mouse Fibroblast Cells. No evidence of cytotoxic response was noted during a seventy-two (72) hour exposure period, and the materials were judged to be negatively cytotoxic.

Q. Is there any way I can get rid of the pores on Sterlitech's Track-Etch filter membranes?

A. If you want to completely get rid of the pores, the easiest way to do so is to dissolve the filter away using chloroform or touch prep.

Q. How do I remove the PVP hydrophilic coating from the surfaces of a polycarbonate membrane filter?

A.  Sterlitech’s polycarbonate membranes are naturally hydrophobic but are coated with PVP to produce a hydrophilic version. While the full range of pores sizes (0.01um-30.0um) are available as hydrophilic filters, we are only able to offer a limited number of pore sizes (0.1um-10.0um) as hydrophobic (PVP-Free).

Fortunately, the PVP can be removed without much hassle.  Boil the membrane(s) for at least 1 hour in deionized ultra-pure water, remove, then air dry the membrane(s).  Once the membrane dries it will be hydrophobic and PVP-Free.

Q. Why are black polycarbonate membranes better than other membranes for counting bacteria?

A. Black polycarbonate membranes are better than cellulose membranes for the direct counting of bacteria, because they have a uniform pore size and a flat surface that retains all of the bacteria on top of the filter. Although cellulose filters also retain all of the bacteria, many become trapped inside the filter where they cannot be counted.

Yes, in some cases within manufacturing capabilities, Sterlitech can provide track-etch membrane filters with non-standard custom specifications for pore diameter, pore density, membrane thickness, and surface treatments.  Please contact us at [email protected] to discuss your application and to inquire about availability.

Thickness, Bubble Point, Pore Size, and Pore Density remain unchanged when stored at a temperature from +5 to 35°C and a humidity of 20 to 80 % for up to 8 years

Q: Why are black dyed polycarbonate track-etch (PCTE) membrane filters preferred for use in epiflourescence microscopy?

A: Black dyed PCTE membrane filters provide the same advantages as regular PCTE membrane filters for microscopy applications, but also have exceptionally low autoflourescence. This permits high contrast between flourescent stained microorganisms and the dark surface of the membrane filters.  The very low autoflourescence of the black dyed PCTE membrane filters also makes them suitable for applications that use automated detection of flourescently labeled microorganisms such as laser scanning cytometry.

Q: Do polycarbonate track-etch (PCTE) membrane filters contain Bisphenol-A (BPA)?

A: Bisphenol-A (BPA) is the monomer used to manufacture polycarbonate. It is not expected that the polycarbonate track-etch (PCTE) membrane filters would contain significant residual amounts of BPA. However, the filters are not analyzed on a lot basis for residual BPA so they cannot be described as BPA free. The user is advised that extreme application conditions, including exposure to high temperatures and/or exposure to incompatible fluids, may attack the molecular structure of the polycarbonate and release trace amounts of BPA. For applications where trace amounts of BPA may cause concern, polyester track-etch (PETE) membrane filters may be considered.

The polycarbonate track-etch (PCTE) membrane filters are quite thin and translucent.  Depending on pore size rating and pore density, the filters may appear transparent or may appear opaque.  Please review https://www.sterlitech.com/blog/post/clarifying-the-matter-of-polycarbonates-membrane-clarity.  In some instances, when PCTE membrane filters with standard specifications appear opaque, Sterlitech can provide custom low pore density filters with the same pore size rating that are transparent.  For comparison, most conventional microporous membrane filters are considerably thicker and cannot be made transparent.  Please contact us at [email protected] to discuss your application and to inquire about the availability custom PCTE membrane filters.

When performing microscopic studies of particles or cells resting on the surface of PCTE membrane filters, some users may find the appearance of the pore edges to be a hindrance.  There are some strategies that can be employed to reduce the appearance of the pore edges.  One of the simplest strategies is to dissolve the membrane, with chloroform or toluene for examples, leaving behind the particles.  Additionally, using a combination of wetting the membrane with a liquid that has the correct refractive index and illuminating the membrane with polarized light, it is possible to make the pores invisible.  The PCTE membrane is birefringent and has two refractive indices, 1.584 and 1.625.  To make the pores invisible, the membrane is wetted with a fluid that has a refractive index of 1.584 and is illuminated with properly oriented polarized light.

The polycarbonate track-etch (PCTE) membrane filters can be dissolved with dipolar aprotic solvents such as dimethylformamide (DMF), dimethyl sulfoxide (DMSO) and n-methyl-2-pyrrolidone (NMP).  The PCTE membrane filters can also be dissolved with the organic chlorinated solvents dichloromethane (DCM or methylene chloride) and trichloromethane (TCM or chloroform).  PCTE membrane filters can also be dissolved with toluene and potentially with other similar aromatic hydrocarbon solvents.

The polyester track-etch (PETE) membrane filters can be dissolved with m-Cresol, o-Chlorophenol, hexafluoroisopropanol, and trifluoroacetic acid (TFA).

Both types of track-etch membranes can be dissolved with elevated temperature sodium hydroxide solutions.

Membranes are used in the study of white blood cell reactions to toxins (chemotaxis), to determine the natural immunity in whole blood. Since immunity is transferable, this could lead to the development of vaccines for treatment of cancer and other diseases. Membranes may be polycarbonate, with or without polyvinylpyrrolidone (PVP). It depends on the type of cells used. Apparently, Neutrophils have a tendency to round up and fall off the membrane when around PVP - not so with some of the other types of cells. Refer to each procedure. Characteristics of PCTE Membrane and Advantages in Chemotaxis Studies Uniform Properties yield reliable, consistent, and reproducible results. Less cell distortion for improved morphology.
Zero leaching of offensive surfactants yields reliable, consistent, and reproducible results.
Smooth, flat surface contributes to high cell visibility on proximal and distal surfaces. Improved morphologic resolution. Easy removal of excess cells from proximal surface.
Thinness of the membrane allows shorter incubation time. More assays made faster and simpler. Chamber sterilization not needed for most studies. Facilitates study of slower moving cells (e.g., monocytes and macrophages).
Low adsorption and absorption of cells causes higher yields. Enhanced radiometric analysis.
Non-staining results in improved contrast. Simplifies optical microscopic analysis routine.
Transparency simplifies optical microscopic analysis routine.
Heat sealable characteristics aids in experimenting with disposable chambers.
Strength of membrane means that less critical handling techniques needed.
Coating Membranes with Gelatin Wash membrane with 0.5% Acetic Acid.
Make a stock gelatin solution with 50mg/10mL water.
Working solution is 1-mL stock to 1-liter water for a light coating.
Then the membranes are placed in a rolling boil of this solution in a beaker for 1 hour.
The membranes are individually pulled out and placed on filter paper to air dry. If an oven is used, use very low temperature for 20 minutes. Air-drying is best in a covered dish left over night. Keep clean.
When the membranes are dry, place them back in their original box.
NOTE: For Chemotaxis, the most important issue is to keep everything at 37 degrees C., the water bath, buffers, glassware, etc. for 1 hour. Studies in cold produce cells that "round up", curl up and fall off. 

We have a Chemical Compatibility Chart that you can use for reference. 

Nominal pore size ratings provide a general indication of filter retention efficiency, meaning some particles equal to or larger than the stated pore size may pass through the filter. Nominal ratings can vary by manufacturer, so filters with the same nominal pore size may not offer equivalent filtration performance.

Absolute pore size ratings are determined through controlled particle or microbial retention testing and represent the smallest particles that are consistently retained by the membrane. These ratings are often correlated with bubble point specifications and are generally more comparable across manufacturers.

Important: Actual filtration performance depends on application conditions, even when using filters with absolute pore size ratings.

The pore size refers to the diameter of the individual pores in a membrane filter.   Pore size is typically specified in micrometers (µm).   Most membranes and filter media actually contain a distribution of pore sizes.  Nominal pore size ratings typically refer to the predominant pore size of a filtration media; pores larger and smaller than the nominal rating may be present.  Absolute pore size ratings typically refer to the largest pore size of a membrane and it is expected that all pores will be equal to or smaller than the absolute rating.

For the polycarbonate track-etch (PCTE) and polyester track-etch (PETE) membrane filters, porosity is the percent of the total surface area occupied by the pores; it typically ranges from <1% to 16%.  For the other membrane filters, porosity is the percent of the total volume occupied by the pores; it typically ranges from 40 to 80%.

You can find the Sterlitech compatibility guide.  It is important to realize that application conditions, such as operating temperature, affect compatibility.  Please contact us at [email protected] if you need assistance.

A. We have several membranes to recommend for gravimetric analysis.

  • Mixed Cellulose Esters (MCE) Membrane Filters, Plain: In gravimetric analysis using ashing techniques, (MCE) Nitrocellulose filters yield a residue of less than 0.045% of their initial weight.  They are hydrophilic with a non-cytotoxic wetting agent extractable level of less than 4% of their weight.
  • Polycarbonate Track-Etch Membranes (PCTE) - 25mm:  Polycarbonate Track-Etch or our Polyester Track-Etch (PETE) membranes are two membranes that offer exceptionally low tare weights, are non-hygroscopic, and exhibit extremely low absorption and adsorption losses.
    Since these membranes are non-hygroscopic, they are particularly well suited for gravimetric analysis.  They do not require drying when used directly out of the package.  If they are wet, they can be dried rapidly and will not pick up moisture from the air during weighing.
  • Glass Fiber Filters & Prefilters:  Glass fiber filters without binders are recommended for analytical and gravimetric determinations.

The bubble point is the minimum amount of pressure required to push air bubbles through the largest pore of a wet membrane.  The bubble point is inversely proportional to the pore diameter, as the pore diameter decreases the bubble point increases and vice versa.

Retention efficiency of membrane filters can be directly measured by challenging the filters with suspensions of standard microorganism cultures or particles of known size.  Unfortunately, such efficiency testing is necessarily destructive.  However, since retention characteristics are dependent on pore size, it is possible to correlate destructive challenge testing results to non-destructive membrane bubble point tests.  In this manner, the relationship between membrane pore size and membrane bubble point is empirically determined.  Typically, a minimum bubble point can be determined and specified for a particular pore size rating.  The bubble point specification is then used for quality control during membrane manufacture.  The bubble point can also be used by the consumer as a nondestructive test to verify membrane integrity before and/or after use.    

Depth filters are constructed with relatively thick filtration media and typically have nominal pore size ratings >1µm. Due to their large void volume, they capture significant amounts of particulate within their pore structure.
Membrane filters are typically composed of polymers that have been chemically processed, resulting in highly porous thin films with microscopic pore structures. Membrane filters typically have absolute pore size ratings <1µm, with some exceptions. Because of their very fine pore structure, membrane filters tend to trap the majority of particles on the surface. However, smaller particles with diameters near or below the pore size rating can be captured within the membrane or pass through the membrane.

Sample packs allow the customer to purchase small quantities of membrane filters at nominal cost, with various diameters and pore sizes as selected.  This allows the customer to preform trials as needed to determine the optimal filter for their application before committing to purchasing standard pack quantities.

 

In most cases, membrane filter samples can be purchased in sizes that are not listed in the standard sample packs.  Please contact us at [email protected] to inquire about availability and pricing.

membrane filters vs separator papers

To ensure ease of use, the membrane filters as stacked in their packaging are interleafed with layers of separator paper.  In most cases, the membrane filters will be white in color except for the track-etch membranes which are colorless and translucent.  In some special cases, the membranes will be dyed dark grey to black in appearance.  In all cases, the separator paper will be a different color than the membrane and is usually not white.  Please contact us at [email protected] if you need assistance.

Ask An Expert

As an industry leader focused in unique micro and sub-micron filtration products, our goal is to support our customers by keeping them at the forefront of their industries. We're here to help with any filtration questions you might have so you can transform your ideas into reality, and tackle those big science challenges. Feel free to reach out using the form below, our experts are ready to serve.