Explore our new PFAS-Free products designed specifically for PFAS testing!
PTFE Coated Vacuum Pumps
PTFE Coated Vacuum Pumps

An economical chemical-resistant diaphragm pump with PTFE coatings. With its chamber coated with PTFE, ROCKER C pumps are resistant to moderate corrosive gases and more cost effective when compared with traditional acid-resistant pumps.

  •  One-Year Warranty
  • Moderate chemical resistance
  • No air pollution, maintenance free
  • Quiet and low vibration
  • Thermal protection device
  • CE / RoHS certification
  • IP 30 protection

Note: 220V/50Hz available upon request

SKU Product Name Price
Rocker 300C, PTFE Coated Chemical Resistant Vacuum Pump, AC110V/60Hz 189300-11 Rocker 300C, PTFE Coated Chemical Resistant Vacuum Pump, AC110V/60Hz
$446.49
Rocker 400C, PTFE Coated Chemical Resistant Vacuum Pump, AC 110V/60Hz 189400-11 Rocker 400C, PTFE Coated Chemical Resistant Vacuum Pump, AC 110V/60Hz
$671.99
Rocker 410C, PTFE Coated Chemical Resistant Vacuum Pump, AC 110V/60Hz 189410-11 Rocker 410C, PTFE Coated Chemical Resistant Vacuum Pump, AC 110V/60Hz
$671.99
Rocker 900C, PTFE Coated Chemical Resistant Vacuum Pump, AC110V, 60Hz 189900-11 Rocker 900C, PTFE Coated Chemical Resistant Vacuum Pump, AC110V, 60Hz
$969.65
Rocker 910C, PTFE Coated Chemical Resistant Vacuum Pump, AC110V, 60Hz 189910-11 Rocker 910C, PTFE Coated Chemical Resistant Vacuum Pump, AC110V, 60Hz
$969.65
Lafil 300C, PTFE Coated Chemical Resistant Vacuum Pump, AC110V/60Hz 197330-11 Lafil 300C, PTFE Coated Chemical Resistant Vacuum Pump, AC110V/60Hz
$762.60
Lafil 300C-VF12, PTFE Coated Chemical Resistant Vacuum Filtration System, AC110V, 60Hz 197331-11 Lafil 300C-VF12, PTFE Coated Chemical Resistant Vacuum Filtration System, AC110V, 60Hz
$974.16
PILOT Economical Chemical Resistant Vacuum Pump 115V / 60 Hz (TLD3000) 1220115 PILOT Economical Chemical Resistant Vacuum Pump 115V / 60 Hz (TLD3000)
$664.40
PILOT Chemical Resistant Diaphragm Vacuum Pump 115V / 60 Hz (TLD5000) 1220114 PILOT Chemical Resistant Diaphragm Vacuum Pump 115V / 60 Hz (TLD5000)
$1,068.33
per page
Set Descending Direction

Frequently Asked Questions

Yes, we do! Check out our Rocker Repair Channel here 

No. Rocker vacuum pumps must be operated on a level, flat surface. Running Rocker 300 or 400 series pumps when they are tilted or not level can cause the prote® protection device inside the inlet filter to close, which may restrict airflow and reduce pump performance.

No. Rocker vacuum pumps should not be moved while operating. Before moving the pump, turn it off and open the inlet to atmosphere to release vacuum. Moving a running Rocker 300 or 400 series pump can cause the prote® protection device inside the inlet filter to close, which may restrict airflow and affect pump performance.

The Prote protection device within the inlet filter may have closed inadvertently. This commonly occurs if the pump was not level, or was moved, while operating. To reset the Prote protection device to the open position, the inlet filter bowl and filter must be removed so that the Prote float can be lowered to the open position. Once the Prote float is in the open position, the filter and bowl can be reinstalled.

Frequently Asked Questions

Yes, we do! Check out our Rocker Repair Channel here 

No. Rocker vacuum pumps must be operated on a level, flat surface. Running Rocker 300 or 400 series pumps when they are tilted or not level can cause the prote® protection device inside the inlet filter to close, which may restrict airflow and reduce pump performance.

No. Rocker vacuum pumps should not be moved while operating. Before moving the pump, turn it off and open the inlet to atmosphere to release vacuum. Moving a running Rocker 300 or 400 series pump can cause the prote® protection device inside the inlet filter to close, which may restrict airflow and affect pump performance.

The Prote protection device within the inlet filter may have closed inadvertently. This commonly occurs if the pump was not level, or was moved, while operating. To reset the Prote protection device to the open position, the inlet filter bowl and filter must be removed so that the Prote float can be lowered to the open position. Once the Prote float is in the open position, the filter and bowl can be reinstalled.

Ask An Expert

As an industry leader focused in unique micro and sub-micron filtration products, our goal is to support our customers by keeping them at the forefront of their industries. We're here to help with any filtration questions you might have so you can transform your ideas into reality, and tackle those big science challenges. Feel free to reach out using the form below, our experts are ready to serve.