Forward Osmosis Cells - Developer

The Sepa FO Cell is a laboratory-scale filtration unit that is designed to evaluate a variety of Osmotically Driven Membrane Processes (ODMP), including Forward Osmosis (FO) and Pressure Retarded Osmosis (PRO). Available in stainless steel or acrylic, for applications requiring visual investigation of hydrodynamic conditions or local fouling intensity. All cells are compatible with our kits, benchtop systems, and skid systems.

Interested in learning how to operate our membrane process equipment?  Check out our MPD channel to watch videos now!

Sepa FO Cell Features and Benefits:

  • Accepts polymeric flat sheet membrane coupons
  • Mimics both laminar or turbulent flow conditions
  • Provides fast and accurate performance data
  • Offers judicious membrane use with small membrane active area
SKU Product Name Est Ship Price
Sepa, Forward Osmosis (FO) Style System, 316 SS 1230061 Sepa, Forward Osmosis (FO) Style System, 316 SS 1-2 days
$9,681.82
Sepa Cell, Forward Osmosis & DCMD, Acrylic 1160007 Sepa Cell, Forward Osmosis & DCMD, Acrylic 1-2 days
$3,497.16
per page
Set Descending Direction

Frequently Asked Questions

General Cross Flow Cell Specifications:

Flow characteristics for a spiral element and flat sheet membrane are significantly different and are really only comparable on a qualitative basis. Variability in the membrane manufacturing process, differences in water composition, test procedures, and test equipment, used in a factory, laboratory, or elsewhere, will impact water flux results.

Reference: Understanding Variation of Experimental Flux and Rejection

lease refer to the following diagram to examine recommended feed flow rates for the crossflow cell you are working with.

 

Post use, the membrane should be rinsed with water after testing and stored in clean water if the storage duration will be less than 24 hours.  If the membrane is rinsed with water and expected to be stored for longer than 48 hours, it is recommended to use a 1% sodium metabisulfite (SMB, chemical formula Na2S2O5) to prevent bacterial growth from occurring. Periodically inspect the membranes for biological growth. If the preservative solution is cloudy you need to replace it.  Renew the preservative solution every month.

Feed spacers are used to mimic the hydrodynamic conditions of large-scale membrane modules by changing the flow regime and creating turbulence inside the feed channel of our membrane test cells.   

For more information on feed spacers incorporated into our test cells, please visit here.

Membranes should be stored in the fridge. Do not allow to freeze. Membranes should be stored away from sunlight. 

The “mil” measurement represents 1/1000th of an inch. Therefore, the thicknesses are 0.017, 0.031, 0.047, 0.065 inches (17, 31, 47, and 65 mil, accordingly). 

Permeate carriers, also known as “permeate water carriers” are aids that are installed between two layers of the flat sheet membranes in a spiral wound element. The main application of this collection layer is to prevent the membrane layers from closing in on each other under high-pressure operations and also facilitate the collection of permeate water. 

 

Product: Flow/pressure regulator valves: 1149421/1149428/1149427

Q: My pressure regulator valve is clogged and it fails to adjust the flow as expected.

A: The valve should be disassembled and cleaned with pressurized air.

No, you cannot use a foulant spacer that is thicker than the test cell feed channel as it may cause damage to the membrane.

Yes, you can use a foulant spacer that is thinner than the test cell feed channel. To do so, you should install a shim, or combination of shims, in the bottom of the feed channel below the foulant spacer so that the combined thickness of the shim(s) and foulant spacer is equal to, or slight less than, the depth of the feed channel.

Yes, you may attempt to reuse flat sheet membranes. However, you may find it difficult to achieve a leak free seal. The cell body o-rings necessarily compress the membrane during installation and the physical action of separating the membrane from the o-rings during removal may cause damage. This damage can impede that ability to achieve a leak free seal when the membrane is reused.

Sterlitech recommends to install all plastic fittings by hand using PTFE tape. If a plastic NPT or compression fitting starts to leak during operational testing, tighten the fitting carefully until the leaking stops. Excessive tightening may break the fitting or damage other components.

If the fittings is broken and stuck in the cell top, use a spiral flute extractor bit or similar tool to release the portion of the fitting in the cell top. If the cell top becomes cracked from removal efforts, a replacement can be purchased.

For supported crossflow membranes, the membrane active side (smooth side) should be facing the feed stream and the support side (rough side) should be facing the permeate stream. For the Sterlitech Sepa CF, CF042, and CF016 test cells, the membrane side (smooth side) would face down toward the feed stream.

These membrane sizes are intended for use in the bench-scale crossflow test cells offered by Sterlitech. Please see the list of flat sheet membranes we offer and their dimensions: HP4750 Stirred Cell: 47 mm (1.85") discs, CF016 cell: 58 x 75 mm (2.26 x 2.95") coupons, CF042 cell: 56 x 115 mm (2.20 x 4.53") coupons, Sepa CF cell: 140 x 190 mm (5.51 x 7.48") coupons, CF047 circular cell: 47 mm discs, CF090 circular cell: 90 mm discs

During high-pressure filtration processes, the membrane sheet inside the cell may deflect outwards into the feed channel.  This occurs due to variations in pressure during operation. This movement can cause rubbing against O-rings which can result in abrasion, possibility rupture, in the membrane sheet. Therefore, a piece of material (shim) can also be placed between the membrane layer and the test cell to take up the free space and help to prevent movement.   

For more information on shims incorporated into our test cells, please visit here

Frequently Asked Questions

General Cross Flow Cell Specifications:

Flow characteristics for a spiral element and flat sheet membrane are significantly different and are really only comparable on a qualitative basis. Variability in the membrane manufacturing process, differences in water composition, test procedures, and test equipment, used in a factory, laboratory, or elsewhere, will impact water flux results.

Reference: Understanding Variation of Experimental Flux and Rejection

lease refer to the following diagram to examine recommended feed flow rates for the crossflow cell you are working with.

 

Post use, the membrane should be rinsed with water after testing and stored in clean water if the storage duration will be less than 24 hours.  If the membrane is rinsed with water and expected to be stored for longer than 48 hours, it is recommended to use a 1% sodium metabisulfite (SMB, chemical formula Na2S2O5) to prevent bacterial growth from occurring. Periodically inspect the membranes for biological growth. If the preservative solution is cloudy you need to replace it.  Renew the preservative solution every month.

Feed spacers are used to mimic the hydrodynamic conditions of large-scale membrane modules by changing the flow regime and creating turbulence inside the feed channel of our membrane test cells.   

For more information on feed spacers incorporated into our test cells, please visit here.

Membranes should be stored in the fridge. Do not allow to freeze. Membranes should be stored away from sunlight. 

The “mil” measurement represents 1/1000th of an inch. Therefore, the thicknesses are 0.017, 0.031, 0.047, 0.065 inches (17, 31, 47, and 65 mil, accordingly). 

Permeate carriers, also known as “permeate water carriers” are aids that are installed between two layers of the flat sheet membranes in a spiral wound element. The main application of this collection layer is to prevent the membrane layers from closing in on each other under high-pressure operations and also facilitate the collection of permeate water. 

 

Product: Flow/pressure regulator valves: 1149421/1149428/1149427

Q: My pressure regulator valve is clogged and it fails to adjust the flow as expected.

A: The valve should be disassembled and cleaned with pressurized air.

No, you cannot use a foulant spacer that is thicker than the test cell feed channel as it may cause damage to the membrane.

Yes, you can use a foulant spacer that is thinner than the test cell feed channel. To do so, you should install a shim, or combination of shims, in the bottom of the feed channel below the foulant spacer so that the combined thickness of the shim(s) and foulant spacer is equal to, or slight less than, the depth of the feed channel.

Yes, you may attempt to reuse flat sheet membranes. However, you may find it difficult to achieve a leak free seal. The cell body o-rings necessarily compress the membrane during installation and the physical action of separating the membrane from the o-rings during removal may cause damage. This damage can impede that ability to achieve a leak free seal when the membrane is reused.

Sterlitech recommends to install all plastic fittings by hand using PTFE tape. If a plastic NPT or compression fitting starts to leak during operational testing, tighten the fitting carefully until the leaking stops. Excessive tightening may break the fitting or damage other components.

If the fittings is broken and stuck in the cell top, use a spiral flute extractor bit or similar tool to release the portion of the fitting in the cell top. If the cell top becomes cracked from removal efforts, a replacement can be purchased.

For supported crossflow membranes, the membrane active side (smooth side) should be facing the feed stream and the support side (rough side) should be facing the permeate stream. For the Sterlitech Sepa CF, CF042, and CF016 test cells, the membrane side (smooth side) would face down toward the feed stream.

These membrane sizes are intended for use in the bench-scale crossflow test cells offered by Sterlitech. Please see the list of flat sheet membranes we offer and their dimensions: HP4750 Stirred Cell: 47 mm (1.85") discs, CF016 cell: 58 x 75 mm (2.26 x 2.95") coupons, CF042 cell: 56 x 115 mm (2.20 x 4.53") coupons, Sepa CF cell: 140 x 190 mm (5.51 x 7.48") coupons, CF047 circular cell: 47 mm discs, CF090 circular cell: 90 mm discs

During high-pressure filtration processes, the membrane sheet inside the cell may deflect outwards into the feed channel.  This occurs due to variations in pressure during operation. This movement can cause rubbing against O-rings which can result in abrasion, possibility rupture, in the membrane sheet. Therefore, a piece of material (shim) can also be placed between the membrane layer and the test cell to take up the free space and help to prevent movement.   

For more information on shims incorporated into our test cells, please visit here

Ask An Expert

As an industry leader focused in unique micro and sub-micron filtration products, our goal is to support our customers by keeping them at the forefront of their industries. We're here to help with any filtration questions you might have so you can transform your ideas into reality, and tackle those big science challenges. Feel free to reach out using the form below, our experts are ready to serve.