Use clean, pure water, which has preferably been filtered in one of the following ways: via RO (reverse osmosis), DI, or has been distilled.

Cleaning Procedure

1. Wash membrane with a 15-20g/L alkaline cleaning solution of sodium hydroxide (NaOH) at a temperature of 85° C for 30 minutes.

2. Rinse membrane with water until pH returns to neutral.

3. For MF and UF membranes, wash membrane with a 5ml/L acid solution of nitric acid (HNO3) or solution of 75% phosphoric acid (H3PO4) at a temperature of 50° C for 15 min. For Fine-UF membranes, wash with a 1ml/L acid solution of 75% phosphoric acid (H3PO4) at a temperature of 50° C for 15 min.

4. Rinse membrane

Back to Ceramic Membranes

Ask An Expert

As an industry leader focused in unique micro and sub-micron filtration products, our goal is to support our customers by keeping them at the forefront of their industries. We're here to help with any filtration questions you might have so you can transform your ideas into reality, and tackle those big science problems. Feel free to reach out using the form below, our experts are ready to serve.