Nanostone flat sheet membranes are being discontinued by the manufacturer. Limited quantities of Nanostone flat sheet membranes is available at the moment, for more information or if you need assistance finding a suitable replacement product, please contact Sterlitech at [email protected].
Nanostone™ Discontinued Nanofiltration Membranes
Series NF4 NF8 Applications Partial Desal, Sulfate Removal Partial Desal pH Range 3-10 3-10 Flux (GFD/psi) 46/150 77/150 MWCO (Daltons) ~150 ~300 Polymer TFC TFC Nanostone™ Discontinued Ultrafiltration Membranes
Series PE5 PE10HR PS35 PA200 PV400 Feed Whey/Milk Protein Whey/Milk Protein Food/Beverage Oily Wastewater Oily Wastewater Applications Concentration, Isolation Concentration, Isolation Clarification Separation Separation pH Range (25°C) 2-10 2-10 2-10 4-10.5 2-10 Flux (lmh/bar) 58 100 1530 350 580 MWCO (Daltons) 6,000 10,000 20,000 100,000 -
May 20, 2016
-
May 16, 2016
Nanostone 1812 Elements are being discontinued by the manufacturer. If you need assistance finding a suitable replacement product, please contact Sterlitech. You can browse other 1812 elements that Sterlitech offers at the moment by clicking here. Limited quantities of Nanostone Flat Sheet Membranes are still available; please contact us for more information.
-
May 09, 2016
Filtering difficult biological solutions? Normally, using a thin membrane filter can pose serious questions:
- “How much liquid can I get through the filter?”
- “When will it clog?”
- “What if my solution is very critical to the project?"
Sterlitech Polyethersulfone (PES) membrane filters have a unique asymmetric pore structure that allows the user to take advantage of this feature; PES can be its own pre-filter and dynamically increase throughput!
Hold a sample piece of this material up to the light at an oblique angle, and you will see a glossy/shiny side, and a more matte/dull side. This sided-ness feature (see Figure 1) is helpful in that the more open area (matte side) has larger entry pores compared to the glossy side; and it should face into the incoming liquid stream for the best results with particulate-heavy liquids. If you were to view an SEM image of the matte side, you may quickly notice the pores seem much larger than the stated pore size, this is normal! Each pore’s ability to
-
May 09, 2016
Forward Osmosis has been known and exploited as a separation process for a variety of applications including water and wastewater treatment, food processing, and power generation since the early 1960’s. Can this process also be applied for air de-humidification? Recent publications and patents have demonstrated that combining capillary condensation with osmosis separation through a semi-permeable membrane, introduced as Osmotic Membrane Dehumidification process, can be an efficient de-humidification method.
In the Osmotic Membrane Dehumidification process, a humid air stream is brought into contact with a semi-permeable membrane, which separates the air stream from an osmotic solution, i.e. draw solution (draw solution is generally a salt solution). Water vapors in the air stream condense by capillary condensation in the pores of the membrane and the condensed water is transferred into the draw solution by osmosis.
Unlike the conventional de-humidification processes, in this process there
-
May 09, 2016
Q: What is membrane pre-conditioning and why is it recommended to pre-condition new flat sheet membranes prior to use in the bench scale filtration cells?
A: Membrane pre-conditioning is a filtration step generally done at a pressure equal to or higher than the test pressure using deionized water as the feed. During this process membrane pores are wetted and the membrane structure may go though compaction or swelling. These changes in the membrane affect both the permeate flux and the rejection values. Therefore, it is recommended to pre-condition the membranes prior to use in the bench scale filtration cells to ensure the membrane performs according to the specs provided by the manufacturer, in terms of both permeate flux and rejection values.
Q: How do you know if membrane is pre-conditioned?
A: It is recommended to filter deionized water through the membrane until the permeate flux reaches a relatively steady value. At this point deionized water can be replaced with feed solution and
-
April 29, 2016
Sterlitech is launching new flat sheet membranes from Microdyn Nadir: NP010 and NP030. Both NF membranes have a Polyethersulfone (PES) active layer and Polyethylene/Polypropylene (PE/PP) support layer. NP010 and NP030 are chemically resistant and can be used at high temperatures, which makes them suitable for applications such as acid/caustic preparation, and for the metal and chemical industry.
Product NP010 NP030 Manufacturer Microdyn Nadir Microdyn Nadir Applications Acid/caustic preparation, metal and chemical industry Acid/caustic preparation, metal and chemical industry pH Range 0-14 0-14 Permeate Flux (lmh1)/psi >200/580 >40/580 Na2SO4 35-75% 80-95% Polymer PES Active layer, PE/PP Support Layer PES Active layer, PE/PP Support Layer 1 LMH stands for Liter per Meter Square Membrane Active Area per Hour These new additions are available in large sheets, as well as in precut coupons for use in the Sepa CF, CF042, and CF016 filtration cells, and most stirred cells. Custom membrane
-
March 31, 2016
The U.S. Department of Labor’s Occupational Safety and Health Administration (OSHA) announced a final rule to improve protections for workers exposed to respirable silica dust. The rule will curb lung cancer, silicosis, chronic obstructive pulmonary disease and kidney disease in America’s workers by limiting their exposure to respirable crystalline silica. The rule changes the Permissible Exposure Limits (PEL) from the current levels of 100µg/m3 of air in general industry (250µg/m3 in construction) to 50µg/m3, averaged over an eight-hour shift. In addition, OSHA affirms in the rule the use of X-Ray Diffraction on silver membrane filters as one of two validated methods for detecting and quantifying airborne crystalline silica in the affected workplace environments.
Sterlitech silver membrane filters are an ideal tool to help keep at-risk workplace environments safe and in accord with the Department of Labor’s final ruling. Affected industries include foundries, abrasive blasting operations,
-
March 17, 2016
Sterlitech is excited to announce the availability of small spiral wound membrane elements. At about 1.8” diameter and 12” in length, 1812 spiral wound elements are perfect for scaling up from flat sheets or as a more complete test before pilot scaling. 1812 elements are also ideal for small-scale production, feasibility studies, and product or process development. Operable up to 600 psi, Sterlitech offers SS316 Housing, which is a universal design compatible with the 1812 elements commercially available here.
Sterlitech currently offers commercially available 1812 spiral wound membrane elements from GE, Nanostone, Sydner, and TriSep in a wide range of MWCO, membrane material and surface properties. To browse our complete selection of 1812 spiral wound elements or to place an order with us, click here.
For more information or if you need assistance to find products suited for a specific application, please contact Sterlitech.
-
March 10, 2016
The Toray UTC-73U flat sheet membrane is being discontinued by the manufacturer and replaced by the Toray UTC-73UAC membrane.
Product UTC-73UAC(New) UTC-73U(Old) Manufacturer Toray Toray Applications Low Energy, High Rejection
Brackish Water TreatmentWater Treatment/Desalination pH Range 2-11 2-11 Permeate Flux (gfd1)/psi 29-40/150 29.5/109 NaCl Rejection 99.5-99.7% 99.4% Polymer Polyamide Polyamide 1 GFD: Gallons per Square Feet Membrane Active Area per Day Discontinued products will include the following Sterlitech Part numbers:
- YM73USP18
- YM73USP195
- YM73USP4205
- YM73USP475
Limited quantities of Toray 73U are still available. For more information or for assistance with finding a suitable replacement, please contact Sterlitech. Additional RO membranes can be found here.