Page 13 - Company News
-
June 06, 2014
Sterlitech Corporation is adding new product options to its line of silt density index (SDI) testing devices. Sterlitech is offering these all-in-one units in response to the industry’s demand for a convenient and durable on-site tool for measuring the fouling capacity of the feed water used in reverse osmosis systems. Silt density index testing quantifies the amount of particulate contamination in a water source and is used to estimate the rate at which membrane fouling will occur, particularly in applications employing reverse osmosis membranes. The SDI of a feed source is measured by running a stream of feed water through a 0.45 micron filter at a constant pressure and calculating the rate at which the flow slows down (ASTM Test Method 4189-07). “Accurate and reliable SDI testing is key to maintaining good efficiency in membrane purification facilities and to help keep operating costs down, especially when dealing with sources like seawater which have a highly variable SDI,” notes
-
May 14, 2014
Sterlitech is shaking up our flat sheet membrane offerings with the addition of new nanofiltration, ultrafiltration, and microfiltration membranes from Synder Filtration. These new membranes encompass a variety of materials and applications. First established in 1989, Synder Filtration has grown into an international supplier of high quality membrane technology. Emphasizing technical expertise, and reliable products, Synder Filtration's membrane technology is ideal for solving industrial and environmental challenges. The table below lists the new membranes and their specs. To browse the complete list of Sterlitech's flat sheet membranes or to place an order, click here. Synder Nanofiltration Membranes
Designation Polymer Molecular Weight Cut-off (MWCO) Rej-Size 25C pH Range Typical Flux/psi GFD@PSI NFX Polyamide TFC 150-300 MWCO Min. 99% MgSO4; Average NaCl = 40% 3-10.5 20-25/110 NFW Polyamide TFC 300-500 MWCO Min. 97% MgSO4; Average NaCl = 20% 4-10 45-50/110 NFG Polyamide -
May 14, 2014
Sterlitech Corporation is adding the EZWaste Safety Vented Carboy to its roster of ergonomic, compact fluid storage and transport equipment. These new, specially vented carboys are designed to help scientists create a safer laboratory environment by reducing the risks of spills and preventing hazardous solvent vapors from infiltrating the lab. “Many organic solvents common to laboratories, like acetonitrile, can give off hazardous vapors, while others, like dimethyl sulfoxide, can easily permeate through the skin when airborne.” says Mark Spatz, founder and President of Sterlitech. “The EZWaste carboy creates a closed waste collection system, preventing spills and minimizing the risks of exposure to personnel from volatile organic compounds.” The EZWaste Safety Vented Carboys are a direct descendent of the EZgrip Carboys currently offered by Sterlitech, which mean they share the same efficient, ergonomic design. What sets the EZWaste apart the normal carboy is a special VersaCap
-
May 14, 2014
Toray is discontinuing the production of some of their reverse osmosis (RO) membranes. These membranes are being replaced in Sterlitech's line-up by the new 70HA, 70AC, 72U, and 82V membranes will be overtaking some of Toray's newly obsolete membranes. The table below lists the specifications of the new and obsolete membranes for easy comparison. To browse our complete selection of RO membranes or to place an order with us, click here.
Designation (SKU) Manufacturer Polymer Molecular Weight Cut-off (MWCO) Rej-Size 25C pH Range Typical Flux/psi GFD@PSI 70B (Obsolete 5/5/14) Toray Polyamide 0 MWCO 99.7 2-11 27/225 70UB (Obsolete 5/5/14) Toray Polyamide 0 MWCO 99.5 2-11 27/110 80E (Obsolete 5/5/14) Toray Polyamide 0 MWCO 99.8 2-11 16/800 80LB (Obsolete 5/5/14) Toray Polyamide 0 MWCO 99.7 2-11 22/800 70HA (YM70HASP18 YM70HASP195 YM70HASP4205 YM70HASP475) Toray Polyamide 0 MWCO 99.0 2-11 23.3/73 70AC (YM70ACSP18 YM70ACSP195 YM70ACSP4205 YM70ACSP475 -
May 14, 2014We're looking forward to showcasing our latest microbiology and life science equipment at the ASM 2014 General Meeting at the Boston Convention Center! Bring all of your burning questions about filtration or lab equipment over to booth #1047, and we'll do our to show you how we can help.
-
April 22, 2014
Spiral wound membrane elements generally offer the best combination of filtration area, flux, and compactness of any cross-flow filtration configuration. But how are they made? To help show the answer to everyone, the Science Channel visited Synder Filtration’s Headquarters in California to film a special segment on membrane filtration. The segment will air during the popular show How It’s Made, on April 24, 2014, at 9 PM Eastern Time (6 PM Pacific Time). About Synder Filtration: First established in 1989, Synder Filtration has grown into an international supplier of high quality membrane technology. Emphasizing customer service, technical expertise, and reliable products, Synder Filtration uses their membrane technology to solve industrial and environmental challenges. To order Synder Flat Sheet Membranes for cross-flow testing, please contact us.
-
April 11, 2014
Toray is discontinuing the production of its UTC-80E reverse osmosis membranes. These membranes are being replaced in Sterlitech's line-up by the new UTC-82E membranes, which share the specifications of the UTC-80E. We've listed their specifications below to aid comparison with other flat sheet membranes:
Designation Polymer Molecular Weight Cut-off (MWCO) Rej-Size pH Range @ 25 °C Typical Flux/psi GFD*@PSI 80E/82E Polyamide 0 MWCO 99.8 2-11 16/800 *GFD = Gallons per square foot of membrane per day The following products are no longer being offered:
- YM80ESP18
- YM80ESP195
- YM80ESP42
- YM80ESP475
You can click here to browse the complete list of reverse osmosis membranes that Sterlitech carries.
-
April 10, 2014
The GM line of ultrafiltration membranes from GE Osmonics is being discontinued. At this time, these membranes do not have any direct replacements, although the GK series, also from GE Osmonics, is used in many of the same applications. We've listed their specifications below to aid comparison with other flat sheet membranes:
Designation Polymer Molecular Weight Cut-off (MWCO) Rej-Size pH Range @ 25 °C Typical Flux/psi GFD*@PSI GM Thin Film 8000 MWCO 8K-PEG 1-11 20/40 *GFD = Gallons per square foot of membrane per day The following products are longer being offered:
- YMGMSP3001
- YMGMSP1905
- YMGMSP425
- YMGMSP475
Although these products are being discontinued, we do have limited quantities of these products remaining. If you need to place an order for any of these products, please contact us. You can also click here to browse the other ultrafiltration membranes that Sterlitech carries.
-
April 01, 2014
Sterlitech Corporation has expanded its line of laminated ePTFE filters with the addition of new Aspire™ membrane filters for microfiltration. With pore sizes ranging from 0.1 micron to 5.0 micron, the Aspire™ membranes broadens Sterlitech’s pore size selection to cover a wider range of applications. The new Aspire™ membranes also include hydrophilic and oleophobic filters. “The new Aspire laminated ePTFE membranes complement our existing laminated and unlaminated PTFE products,” states Mark Spatz, president of Sterlitech. “The hydrophilic and oleophobic membranes also introduce capabilities that our previous ePTFE products didn’t have.” Expanding PTFE creates a dense, web-like structure with billions of microscopic pores, which trap particulates and allow liquids or gas to flow through. Sterlitech offers Aspire ePTFE membrane filters in packs of 200 mm x 250 mm sheets with pore sizes ranging from 0.1 microns to 5.0 microns. The membranes are supported by a layer of polypropylene
-
March 19, 2014
The EW and JW line of ultrafiltration membranes from GE Osmonics is being discontinued. At this time, these membranes do not have any direct replacements, but we've listed their specifications below to aid comparison for similar products:
Designation Polymer Molecular Weight Cut-off (MWCO) Rej-Size pH Range @ 25 °C Typical Flux/psi GFD*@PSI EW Polysulfone 60000 MWCO 60K-Dextran 1-12 300/25 JW PVDF 30000 MWCO 25K - 50K 1-11 275/30 *GFD = Gallons per square foot of membrane per day The following products are longer being offered:
- YMEWSP3001
- YMEWSP1905
- YMEWSP425
- YMEWSP475
- YMJWSP3001
- YMJWSP1905
- YMJWSP425
- YMJWSP475
Although these products are being discontinued, we do have limited quantities of these products remaining. If you need to place an order for either of these products, please contact us. You can also click here to browse the other ultrafiltration membranes that Sterlitech carries.