Check out our new Sartorius Product Line Shop Sartorius

Aluminum Oxide Membranes

Aluminum oxide (AO) membranes feature uniform, densely-packed honeycomb pore structures that contribute to precise retention and high porosity characteristics. Composed of pure anodized aluminum, these filters have essentially no organic extractables.

*AO Membranes are fragile.  Please see blog on handling tips

Virtually transparent when wet, this material shows minimal autofluorescence and exhibits excellent surface retention properties. This makes it ideal for use in microscopic analyses. AO membranes are non-cytotoxic and have good biocompatibility; features that enable use as cell culture subtrate. Additionally, their uniform, noninterconnected pores present a suitable template for the synthesis of nanostructures.

We provide the filters and technical support to help you take your breakthrough product from an idea to a prototype, to commercial scale.

 
SKUProduct Name Pore Size Diameter (mm) Pack Size Est Ship Price
1360001 Aluminum Oxide Membrane Filters, 0.02 Micron, 13mm, 10/pk 0.02 13 10 1-2 days
$92.72
1360010 Aluminum Oxide Membrane Filters, 0.02 Micron, 13mm, 50/pk 0.02 13 50 1-2 days
$418.50
1360002 Aluminum Oxide Membrane Filters, 0.02 Micron, 25mm, 10/pk 0.02 25 10 1-2 days
$211.74
1360011 Aluminum Oxide Membrane Filters, 0.02 Micron, 25mm, 50/pk 0.02 25 50 1-2 days
$952.82
1360003 Aluminum Oxide Membrane Filters, 0.02 Micron, 47mm, 10/pk 0.02 47 10 1-2 days
$300.70
1360012 Aluminum Oxide Membrane Filters, 0.02 Micron, 47mm, 50/pk 0.02 47 50 1-2 days
$1,502.04
1360004 Aluminum Oxide Membrane Filters, 0.1 Micron, 13mm, 10/pk 0.1 13 10 1-2 days
$92.72
1360013 Aluminum Oxide Membrane Filters, 0.1 Micron, 13mm, 50/pk 0.1 13 50 1-2 days
$418.50
1360005 Aluminum Oxide Membrane Filters, 0.1 Micron, 25mm, 10/pk 0.1 25 10 1-2 days
$211.74
1360014 Aluminum Oxide Membrane Filters, 0.1 Micron, 25mm, 50/pk 0.1 25 50 1-2 days
$952.82
1360006 Aluminum Oxide Membrane Filters, 0.1 Micron, 47mm, 10/pk 0.1 47 10 1-2 days
$300.70
1360015 Aluminum Oxide Membrane Filters, 0.1 Micron, 47mm, 50/pk 0.1 47 50 1-2 days
$1,502.04
1360007 Aluminum Oxide Membrane Filters, 0.2 Micron, 13mm, 10/pk 0.2 13 10 1-2 days
$92.72
1360016 Aluminum Oxide Membrane Filters, 0.2 Micron, 13mm, 50/pk 0.2 13 50 1-2 days
$418.50
1360008 Aluminum Oxide Membrane Filters, 0.2 Micron, 25mm, 10/pk 0.2 25 10 1-2 days
$211.74
1360017 Aluminum Oxide Membrane Filters, 0.2 Micron, 25mm, 50/pk 0.2 25 50 1-2 days
$952.82
1360009 Aluminum Oxide Membrane Filters, 0.2 Micron, 47mm, 10/pk 0.2 47 10 1-2 days
$300.70
1360018 Aluminum Oxide Membrane Filters, 0.2 Micron, 47mm, 50/pk 0.2 47 50 1-2 days
$1,502.04
per page
Set Descending Direction

Aluminum Oxide Filter Applications & Features

Applications:

  • HPLC sample and mobile phase filtration
  • Filtration of aggressive organic solvents
  • Virus concentration and analysis
  • Analysis of micro plastic in water
  • Epifluorescence microscopy
  • Synthesis of nanostructures (e.g. nanotubes)

Features:

  • Fast filtration, efficient separation and high purity
  • High number of tightly controlled pores in honeycomb shape
  • Free of organic extractables and leachables
  • Minimum adsorption
  • Transparent when wet

Aluminum Oxide Filter Specifications

Pore Size 0.02 µm 0.1 µm 0.2 µm
Thickness 60 µm 60 µm 60 µm
Porosity 25-50% 25-50% 25-50%
Max Temp. 400°C (752°F) 400°C (752°F) 400°C (752°F)
Autoclavable Yes Yes Yes
Hydrophilic Yes Yes Yes
Solvent Resistance High High High
pH Range 6-8 6-8 6-8
Protein Adsorption Low Low Low
Refractive Index 1.6 1.6 1.6
Support Ring No No No

Documentation

Frequently Asked Questions


The pores of microporous membrane filters act as small capillaries.  When hydrophilic membranes come into contact with water, capillary action associated with surface tension forces causes the water to spontaneously enter and fill the pores.  In this manner, the membranes are easily wetted and allow the bulk flow of water through the pores.  Once wetted, hydrophilic membranes will not allow the bulk flow of air or other gasses, unless they are applied at pressures greater than the membrane’s bubble point.

Hydrophilic membrane filters are typically used with water and aqueous solutions.  They can also be used with compatible non-aqueous fluids.  Hydrophilic membrane filters are typically not used for air, gas or vent filtration since the filters would block flow if inadvertently wetted, by condensation for example.

When hydrophobic membranes come into contact with water, surface tension forces act to repel the water from the pores.  Water will not enter the pores and the membranes will act as a barrier to water flow, unless the water is applied at pressures greater than the membrane’s water entry pressure.  Low surface tension fluids, such as alcohols, can spontaneously enter and fill the pores of hydrophobic membranes.  Once all the air in the pores is displaced, there are no longer any surface tension forces and water can easily enter the pores, displace the low surface tension fluid, and pass through the membrane.  The membrane will then allow bulk flow of water for as long as the pore remain water filled.  If the membrane is allowed to dry (i.e. air enters the pores), then it must be pre-wet with a low surface tension fluid again prior to use with water.

Hydrophobic membrane filters are typically used with compatible non-aqueous fluids.  They are also commonly used as air, gas, or vent filters.  Hydrophobic membrane filters are sometimes used with water or aqueous solutions; and, in these applications, they must first be prewet with a low surface tension, water miscible fluid prior to use.

Yes, the aluminum oxide membrane filters are somewhat asymmetric. The shiny side of the filter is the surface with the smallest pores. The shiny side faces up in the packaging.

AO Membranes are extremly brittle. Click here to see our blog for handling the membranes

Aluminum oxide is free of organic extractables and leachables and shows minimum adsorption.

Unfortunately, we are unable to supply the aluminum oxide membrane filters with custom diameters. Please contact us at [email protected] to inquire about alternatives.

Yes, the aluminum oxide membrane filters are somewhat asymmetric. The shiny side of the filter is the surface with the smallest pores. The shiny side faces up in the packaging.

Q. What is the difference between nominal and absolute pore size ratings?

Nominal pore size ratings are provided as a general indication of filter retention.  It is understood that some quantity of particles greater than, and equal to, the nominal pore size ratings will pass through the filters into the filtrate.  Some manufactures may associate nominal pore size ratings with percentage filtration efficiencies. Nominal pore size ratings vary from manufacturer to manufacturer and, consequently, are not necessarily equivalent. Filters from different manufactures with similar nominal pore size ratings may not actually exhibit similar retention characteristics.

Absolute pore size ratings are typically based on retention studies performed using challenge suspensions of standard microorganism cultures or particles of known size. Absolute pore size ratings represent the size of the smallest microorganisms or particles completely retained during these studies. Absolute pore size ratings are almost always correlated to bubble point specifications that are used for quality control during membrane manufacturing. For the most part, absolute pore size ratings, especially those based on microbial retention, are comparable from manufacturer to manufacturer. There is more uncertainty for absolute pore size ratings based on particle retention studies, especially for pore size ratings <0.2µm, since there are no standard methods for these studies.

Regardless of pore size ratings, it is important to understand that application conditions do influence particle retention. Even filters with absolute pore size ratings can be operated in conditions that will allow unexpectedly sized particles to pass.


The Sterlitech aluminum oxide membrane filters are not available with perimeter support rings.  However, when handled with care, they are suitable alternatives to competitive aluminum oxide membrane filters with ring supports. 

The pore size refers to the diameter of the individual pores in a membrane filter.   Pore size is typically specified in micrometers (µm).   Most membranes and filter media actually contain a distribution of pore sizes.  Nominal pore size ratings typically refer to the predominant pore size of a filtration media; pores larger and smaller than the nominal rating may be present.  Absolute pore size ratings typically refer to the largest pore size of a membrane and it is expected that all pores will be equal to or smaller than the absolute rating.

For the polycarbonate track-etch (PCTE) and polyester track-etch (PETE) membrane filters, porosity is the percent of the total surface area occupied by the pores; it typically ranges from <1% to 16%.  For the other membrane filters, porosity is the percent of the total volume occupied by the pores; it typically ranges from 40 to 80%.

The aluminum oxide membrane filters can be readily dissolved with sodium hydroxide solutions at 1M concentration or higher.  The time required to dissolve the membrane can be reduced by elevating the temperature and/or increasing the concentration.

You can find the Sterlitech compatibility guide.  It is important to realize that application conditions, such as operating temperature, affect compatibility.  Please contact us at [email protected] if you need assistance.

Yes, the Sterlitech aluminum oxide membrane filters can be used as alternatives for the Whatman Anodisc filters. Our alumina filters do not have perimeter support rings, so somewhat greater care must be taken when handling the filters to avoid damage.

The bubble point is the minimum amount of pressure required to push air bubbles through the largest pore of a wet membrane.  The bubble point is inversely proportional to the pore diameter, as the pore diameter decreases the bubble point increases and vice versa.

Retention efficiency of membrane filters can be directly measured by challenging the filters with suspensions of standard microorganism cultures or particles of known size.  Unfortunately, such efficiency testing is necessarily destructive.  However, since retention characteristics are dependent on pore size, it is possible to correlate destructive challenge testing results to non-destructive membrane bubble point tests.  In this manner, the relationship between membrane pore size and membrane bubble point is empirically determined.  Typically, a minimum bubble point can be determined and specified for a particular pore size rating.  The bubble point specification is then used for quality control during membrane manufacture.  The bubble point can also be used by the consumer as a nondestructive test to verify membrane integrity before and/or after use.    

Depth filters are constructed with relatively thick filtration media and typically have nominal pore size ratings >1µm. Due to their large void volume, they capture significant amounts of particulate within their pore structure.
Membrane filters are typically composed of polymers that have been chemically processed, resulting in highly porous thin films with microscopic pore structures. Membrane filters typically have absolute pore size ratings <1µm, with some exceptions. Because of their very fine pore structure, membrane filters tend to trap the majority of particles on the surface. However, smaller particles with diameters near or below the pore size rating can be captured within the membrane or pass through the membrane.

membrane filters vs separator papers

To ensure ease of use, the membrane filters as stacked in their packaging are interleafed with layers of separator paper.  In most cases, the membrane filters will be white in color except for the track-etch membranes which are colorless and translucent.  In some special cases, the membranes will be dyed dark grey to black in appearance.  In all cases, the separator paper will be a different color than the membrane and is usually not white.  Please contact us at [email protected] if you need assistance.