Explore our new PFAS-Free products designed specifically for PFAS testing!
Nanofiltration (NF) Membranes
Sterlitech Nanofiltration Flat Sheet Membranes

Sterlitech nanofiltration (NF) flat sheet membranes may be used in our process filtration units for evaluation or for any of your general separations needs.

Sterlitech carries four brands of nanofiltration (NF) membranes:

  • Veolia flat sheet membranes 
  • TriSep flat sheet membranes
  • FilmTec™ flat sheet membranes 
  • Synder Filtration flat sheet membranes 

Please note: custom sample selections of our flat sheet membranes are also available upon request. 


Detailed List Of Sterlitech Flat Sheet Membranes


Contact us to build your own NF Membrane Assortment Pack Here

View the latest news about Sterlitech Flat Sheet Membranes here.

Go Back To The Flat Sheet Membranes Main Page

SKU Product Name Designation Polymer Size Pack Size Est Ship Price
1121900 Dow Filmtec Flat Sheet Membrane, NF, PA-TFC, 90mm, 5/Pk NF Polyamide-TFC 90 mm 5 5-7 days
$227.93
YMNF1905 Dow Filmtec Flat Sheet Membrane, NF, PA-TFC, Sepa, 5/Pk NF Polyamide-TFC Sepa 5 5-7 days
$296.26
YMNF2704060 Dow Filmtec Flat Sheet Membrane, NF270, PA-TFC, NF, 1016 x 1524mm, 1/Pk NF270 Polyamide-TFC 1016 x 1524mm 1 5-7 days
$538.45
YMNF2703001 Dow Filmtec Flat Sheet Membrane, NF270, PA-TFC, NF, 305 x 305mm, 1/Pk NF270 Polyamide-TFC 305 x 305 mm 1 5-7 days
$127.20
YMNF270475 Dow Filmtec Flat Sheet Membrane, NF270, PA-TFC, NF, 47mm, 5/Pk NF270 Polyamide-TFC 47 mm 5 5-7 days
$83.88
1121902 Dow Filmtec Flat Sheet Membrane, NF270, PA-TFC, NF, 90mm, 5/Pk NF270 Polyamide-TFC 90 mm 5 5-7 days
$227.93
1121008 Dow Filmtec Flat Sheet Membrane, NF270, PA-TFC, NF, CF016, 5/Pk NF270 Polyamide-TFC CF016 5 5-7 days
$167.78
YMNF2704205 Dow Filmtec Flat Sheet Membrane, NF270, PA-TFC, NF, CF042, 5/Pk NF270 Polyamide-TFC CF042 5 5-7 days
$167.78
YMNF2701905 Dow Filmtec Flat Sheet Membrane, NF270, PA-TFC, NF, Sepa, 5/Pk NF270 Polyamide-TFC Sepa 5 5-7 days
$296.26
YMNF904060 Dow Filmtec Flat Sheet Membrane, NF90, PA-TFC, NF, 1016 x 1524mm, 1/Pk NF90 Polyamide-TFC 1016 x 305 mm 1 5-7 days
$538.45
YMNF903001 Dow Filmtec Flat Sheet Membrane, NF90, PA-TFC, NF, 305 x 305mm, 1/Pk NF90 Polyamide-TFC 305 x 305 mm 1 5-7 days
$127.20
YMNF90475 Dow Filmtec Flat Sheet Membrane, NF90, PA-TFC, NF, 47mm, 5/Pk NF90 Polyamide-TFC 47 mm 5 5-7 days
$83.88
1121904 Dow Filmtec Flat Sheet Membrane, NF90, PA-TFC, NF, 90mm, 5/Pk NF90 Polyamide-TFC 90 mm 5 5-7 days
$227.93
1121012 Dow Filmtec Flat Sheet Membrane, NF90, PA-TFC, NF, CF016, 5/Pk NF90 Polyamide-TFC CF016 5 5-7 days
$167.78
YMNF904205 Dow Filmtec Flat Sheet Membrane, NF90, PA-TFC, NF, CF042, 5/Pk NF90 Polyamide-TFC CF042 5 5-7 days
$167.78
YMNF901905 Dow Filmtec Flat Sheet Membrane, NF90, PA-TFC, NF, Sepa, 5/Pk NF90 Polyamide-TFC Sepa 5 5-7 days
$296.26
YMNF4060 Dow Filmtec Flat Sheet Membrane, PA-TFC, NF, 1016 x 1524mm, 1/Pk NF Polyamide-TFC 1016 x 1524mm 1 5-7 days
$538.44
YMNF3001 Dow Filmtec Flat Sheet Membrane, PA-TFC, NF, 305 x 305mm, 1/Pk NF Polyamide-TFC 305 x 305 mm 1 5-7 days
Call for Price
View Details
YMNF475 Dow Filmtec Flat Sheet Membrane, PA-TFC, NF, 47mm, 5/Pk NF Polyamide-TFC 47 mm 5 5-7 days
Call for Price
View Details
YMNF4205 Dow Filmtec Flat Sheet Membrane, PA-TFC, NF, CF042, 5/Pk NF Polyamide-TFC CF042 5 5-7 days
Call for Price
View Details
1122095 Dow Filmtec Flat Sheet Membrane, XUS2909, PA-TFC, NF, 305 x 305mm, 1/Pk XUS2909 Polyamide-TFC 305 x 305 mm 1 5-7 days
$127.20
1122096 Dow Filmtec Flat Sheet Membrane, XUS2909, PA-TFC, NF, 47mm, 5/pk XUS2909 Polyamide-TFC 47 mm 5 5-7 days
$83.88
1122097 Dow Filmtec Flat Sheet Membrane, XUS2909, PA-TFC, NF, 90mm, 5/pk XUS2909 Polyamide-TFC 90 mm 5 5-7 days
$227.93
1122098 Dow Filmtec Flat Sheet Membrane, XUS2909, PA-TFC, NF, CF016, 5/pk XUS2909 Polyamide-TFC CF016 5 5-7 days
$167.78
1122099 Dow Filmtec Flat Sheet Membrane, XUS2909, PA-TFC, NF, CF042, 5/pk XUS2909 Polyamide-TFC CF042 5 5-7 days
$167.78
1122100 Dow Filmtec Flat Sheet Membrane, XUS2909, PA-TFC, NF, SEPA, 5/pk XUS2909 Polyamide-TFC Sepa 5 5-7 days
$296.26
1121928 Evonik Flat Sheet Membrane, Puramem Flux, NF, 90mm, 5/Pk Puramem Flux Silicone-coated PAN 90 mm 5 5-7 days
$227.93
1121930 Evonik Flat Sheet Membrane, Puramem Performance, NF, 90mm, 5/Pk Puramem Performance Silicone-coated PAN 90 mm 5 5-7 days
$227.93
1120787 Evonik Flat Sheet Membrane, Puramem Performance, NF, CF042, 5/pk Puramem Performance Silicone-coated PAN CF042 5 1-2 days
$287.04
1121934 Evonik Flat Sheet Membrane, Puramem Selective, NF, 90mm, 5/Pk Puramem Selective Silicone-coated PAN 90 mm 5 5-7 days
$227.93
YMNP0103001 Microdyn Nadir Flat Sheet Membrane, NP010, PES, NF, 297 x 210mm, 1/pk NP010 PES 297 x 210 mm 1 5-7 days
$102.55
YMNP010475 Microdyn Nadir Flat Sheet Membrane, NP010, PES, NF, 47mm, 5/Pk NP010 PES 47 mm 5 5-7 days
$83.88
1121936 Microdyn Nadir Flat Sheet Membrane, NP010, PES, NF, 90mm, 5/Pk NP010 PES 90 mm 5 5-7 days
$227.93
1121016 Microdyn Nadir Flat Sheet Membrane, NP010, PES, NF, CF016, 5/Pk NP010 PES CF016 5 5-7 days
$167.78
YMNP0104205 Microdyn Nadir Flat Sheet Membrane, NP010, PES, NF, CF042, 5/Pk NP010 PES CF042 5 5-7 days
$167.78
YMNP0101905 Microdyn Nadir Flat Sheet Membrane, NP010, PES, NF, Sepa, 5/Pk NP010 PES Sepa 5 5-7 days
$296.26
YMNP0303001 Microdyn Nadir Flat Sheet Membrane, NP030, PES, NF, 297 x 210mm, 1/pk NP030 PES 297 x 210 mm 1 5-7 days
$102.55
YMNP030475 Microdyn Nadir Flat Sheet Membrane, NP030, PES, NF, 47mm, 5/Pk NP030 PES 47 mm 5 5-7 days
$83.88
1121938 Microdyn Nadir Flat Sheet Membrane, NP030, PES, NF, 90mm, 5/Pk NP030 PES 90 mm 5 5-7 days
$227.93
1121018 Microdyn Nadir Flat Sheet Membrane, NP030, PES, NF, CF016, 5/Pk NP030 PES CF016 5 5-7 days
$167.78
YMNP0304205 Microdyn Nadir Flat Sheet Membrane, NP030, PES, NF, CF042, 5/Pk NP030 PES CF042 5 5-7 days
$167.78
YMNP0301905 Microdyn Nadir Flat Sheet Membrane, NP030, PES, NF, Sepa, 5/Pk NP030 PES Sepa 5 5-7 days
$296.26
YMNDX10001 Synder Flat Sheet Membrane, NDX, PA-TFC, NF, 1000 x 1000mm, 1/Pk NDX Polyamide TFC 1000 x 1000 mm 1 2 weeks
$212.05
YMNDX3001 Synder Flat Sheet Membrane, NDX, PA-TFC, NF, 305 x 305mm, 1/Pk NDX Polyamide TFC 305 x 305 mm 1 5-7 days
$127.20
YMNDX475 Synder Flat Sheet Membrane, NDX, PA-TFC, NF, 47mm, 5/Pk NDX Polyamide TFC 47 mm 5 5-7 days
$83.88
1121958 Synder Flat Sheet Membrane, NDX, PA-TFC, NF, 90mm, 5/Pk NDX Polyamide-TFC 90 mm 5 5-7 days
$227.93
1121007 Synder Flat Sheet Membrane, NDX, PA-TFC, NF, CF016, 5/Pk NDX Polyamide-TFC CF016 5 5-7 days
$167.78
YMNDX4205 Synder Flat Sheet Membrane, NDX, PA-TFC, NF, CF042, 5/Pk NDX Polyamide TFC CF042 5 5-7 days
$167.78
YMNDX1905 Synder Flat Sheet Membrane, NDX, PA-TFC, NF, Sepa 5/Pk NDX Polyamide TFC Sepa 5 5-7 days
$296.26
YMNFG10001 Synder Flat Sheet Membrane, NFG, PA-TFC, NF, 1000 x 1000mm, 1/Pk NFG Polyamide TFC 1000 x 1000 mm 1 1-2 days
$212.05
YMNFG3001 Synder Flat Sheet Membrane, NFG, PA-TFC, NF, 305 x 305mm, 1/Pk NFG Polyamide TFC 305 x 305 mm 1 5-7 days
$127.20
YMNFG475 Synder Flat Sheet Membrane, NFG, PA-TFC, NF, 47mm, 5/Pk NFG Polyamide TFC 47 mm 5 5-7 days
$83.88
1121960 Synder Flat Sheet Membrane, NFG, PA-TFC, NF, 90mm, 5/Pk NFG Polyamide-TFC 90 mm 5 5-7 days
$227.93
1121013 Synder Flat Sheet Membrane, NFG, PA-TFC, NF, CF016, 5/Pk NFG Polyamide-TFC CF016 5 5-7 days
$167.78
YMNFG4205 Synder Flat Sheet Membrane, NFG, PA-TFC, NF, CF042, 5/Pk NFG Polyamide TFC CF042 5 5-7 days
$167.78
YMNFG1905 Synder Flat Sheet Membrane, NFG, PA-TFC, NF, Sepa, 5/Pk NFG Polyamide TFC Sepa 5 5-7 days
$296.26
1121829 Synder Flat Sheet Membrane, NFS, PA-TFC, NF, 1000 x 1000 mm, 1/Pk NFS Polyamide-TFC 1000 x 1000 mm 1 5-7 days
$212.05
1122107 Synder Flat Sheet Membrane, NFS, PA-TFC, NF, 305 x 305 mm, 1/Pk NFS Polyamide-TFC 305 x 305 mm 1 5-7 days
$127.20
1122109 Synder Flat Sheet Membrane, NFS, PA-TFC, NF, 47mm, 5/Pk NFS Polyamide-TFC 47 mm 5 5-7 days
$83.88
1121962 Synder Flat Sheet Membrane, NFS, PA-TFC, NF, 90mm, 5/Pk NFS Polyamide-TFC 90 mm 5 5-7 days
$227.93
1122106 Synder Flat Sheet Membrane, NFS, PA-TFC, NF, CF016, 5/Pk NFS Polyamide-TFC CF016 5 5-7 days
$167.77
1122104 Synder Flat Sheet Membrane, NFS, PA-TFC, NF, CF042, 5/Pk NFS Polyamide-TFC CF042 5 5-7 days
$167.77
1121830 Synder Flat Sheet Membrane, NFS, PA-TFC, NF, Sepa, 5/Pk NFS Polyamide-TFC Sepa 5 5-7 days
$296.26
YMNFW10001 Synder Flat Sheet Membrane, NFW, PA-TFC, NF, 1000 x 1000mm, 1/Pk NFW Polyamide TFC 1000 x 1000 mm 1 2 weeks
$212.05
YMNFW3001 Synder Flat Sheet Membrane, NFW, PA-TFC, NF, 305 x 305mm, 1/Pk NFW Polyamide TFC 305 x 305 mm 1 5-7 days
$127.20
YMNFW475 Synder Flat Sheet Membrane, NFW, PA-TFC, NF, 47mm, 5/Pk NFW Polyamide TFC 47 mm 5 5-7 days
$83.88
1121964 Synder Flat Sheet Membrane, NFW, PA-TFC, NF, 90mm, 5/Pk NFW Polyamide-TFC 90 mm 5 5-7 days
$227.93
1121014 Synder Flat Sheet Membrane, NFW, PA-TFC, NF, CF016, 5/Pk NFW Polyamide-TFC CF016 5 5-7 days
$167.78
YMNFW4205 Synder Flat Sheet Membrane, NFW, PA-TFC, NF, CF042, 5/Pk NFW Polyamide TFC CF042 5 5-7 days
$167.78
YMNFW1905 Synder Flat Sheet Membrane, NFW, PA-TFC, NF, Sepa, 5/Pk NFW Polyamide TFC Sepa 5 5-7 days
$296.26
YMNFX10001 Synder Flat Sheet Membrane, NFX, PA-TFC, NF, 1000 x 1000mm, 1/Pk NFX Polyamide TFC 1000 x 1000 mm 1 2 weeks
$212.05
YMNFX3001 Synder Flat Sheet Membrane, NFX, PA-TFC, NF, 305 x 305mm, 1/Pk NFX Polyamide TFC 305 x 305 mm 1 5-7 days
$127.20
YMNFX475 Synder Flat Sheet Membrane, NFX, PA-TFC, NF, 47mm, 5/Pk NFX Polyamide TFC 47 mm 5 5-7 days
$83.88
1121966 Synder Flat Sheet Membrane, NFX, PA-TFC, NF, 90mm, 5/Pk NFX Polyamide-TFC 90 mm 5 5-7 days
$227.93
1121015 Synder Flat Sheet Membrane, NFX, PA-TFC, NF, CF016, 5/Pk NFX Polyamide-TFC CF016 5 5-7 days
$167.78
YMNFX4205 Synder Flat Sheet Membrane, NFX, PA-TFC, NF, CF042, 5/Pk NFX Polyamide TFC CF042 5 5-7 days
$167.78
YMNFX1905 Synder Flat Sheet Membrane, NFX, PA-TFC, NF, Sepa, 5/Pk NFX Polyamide TFC Sepa 5 5-7 days
$296.26
YMSB903001 TriSep Flat Sheet Membrane, SB90, CA Blend, NF, 1016 x 305mm, 1/Pk SB90 Cellulose Acetate 1016 x 305 mm 1 5-7 days
$152.52
YMSB90475 TriSep Flat Sheet Membrane, SB90, CA Blend, NF, 47mm, 5/Pk SB90 Cellulose Acetate 47 mm 5 5-7 days
$83.88
1121988 TriSep Flat Sheet Membrane, SB90, CA Blend, NF, 90mm, 5/Pk SB90 Celulose Acetate Blend 90 mm 5 5-7 days
$227.93
1121031 TriSep Flat Sheet Membrane, SB90, CA Blend, NF, CF016, 5/Pk SB90 Cellulose Acetate CF016 5 5-7 days
$167.78
YMSB904205 TriSep Flat Sheet Membrane, SB90, CA Blend, NF, CF042, 5/Pk SB90 Cellulose Acetate CF042 5 5-7 days
$167.78
YMSB901905 TriSep Flat Sheet Membrane, SB90, CA Blend, NF, Sepa, 5/Pk SB90 Cellulose Acetate Sepa 5 5-7 days
$296.26
YMSBNF3001 TriSep Flat Sheet Membrane, SBNF, CA, NF, 1016 x 305mm, 1/pk SBNF Cellulose Acetate 1016 x 305 mm 1 5-7 days
$152.52
YMSBNF475 TriSep Flat Sheet Membrane, SBNF, CA, NF, 47mm, 5/Pk SBNF Cellulose Acetate 47 mm 5 5-7 days
$83.88
1121990 TriSep Flat Sheet Membrane, SBNF, CA, NF, 90mm, 5/Pk SBNF Celulose Acetate 90 mm 5 5-7 days
$227.93
1121032 TriSep Flat Sheet Membrane, SBNF, CA, NF, CF016, 5/Pk SBNF Cellulose Acetate CF016 5 5-7 days
$167.78
YMSBNF4205 TriSep Flat Sheet Membrane, SBNF, CA, NF, CF042, 5/Pk SBNF Cellulose Acetate CF042 5 5-7 days
$167.78
YMSBNF1905 TriSep Flat Sheet Membrane, SBNF, CA, NF, Sepa, 5/Pk SBNF Cellulose Acetate Sepa 5 5-7 days
$296.26
YMTS403001 TriSep Flat Sheet Membrane, TS40, PPA, NF, 1016 x 305mm, 1/Pk TS40 Polypiperazine amide 1016 x 305 mm 1 5-7 days
$152.52
YMTS40475 TriSep Flat Sheet Membrane, TS40, PPA, NF, 47mm, 5/Pk TS40 Polypiperazine amide 47 mm 5 5-7 days
$83.88
1121992 TriSep Flat Sheet Membrane, TS40, PPA, NF, 90mm, 5/Pk TS40 Polypiperazine amide 90 mm 5 5-7 days
$227.93
1121040 TriSep Flat Sheet Membrane, TS40, PPA, NF, CF016, 5/Pk TS40 PPA CF016 5 5-7 days
$167.78
YMTS404205 TriSep Flat Sheet Membrane, TS40, PPA, NF, CF042, 5/Pk TS40 Polypiperazine amide CF042 5 5-7 days
$167.78
YMTS401905 TriSep Flat Sheet Membrane, TS40, PPA, NF, Sepa, 5/Pk TS40 Polypiperazine amide Sepa 5 5-7 days
$296.26
YMTS803001 TriSep Flat Sheet Membrane, TS80, PA, NF, 1016 x 305mm, 1/Pk TS80 Polyamide-TFC 1016 x 305 mm 1 5-7 days
$152.52
YMTS80475 TriSep Flat Sheet Membrane, TS80, PA, NF, 47mm, 5/Pk TS80 Polyamide-TFC 47 mm 5 5-7 days
$83.88
1121994 TriSep Flat Sheet Membrane, TS80, PA, NF, 90mm, 5/Pk TS80 Polyamide-TFC 90 mm 5 5-7 days
$227.93
1121041 TriSep Flat Sheet Membrane, TS80, PA, NF, CF016, 5/Pk TS80 Polyamide-TFC CF016 5 5-7 days
$167.78
YMTS804205 TriSep Flat Sheet Membrane, TS80, PA, NF, CF042, 5/Pk TS80 Polyamide-TFC CF042 5 5-7 days
$167.78
YMTS801905 TriSep Flat Sheet Membrane, TS80, PA, NF, Sepa, 5/Pk TS80 Polyamide-TFC Sepa 5 5-7 days
$296.26
YMXN453001 TriSep Flat Sheet Membrane, XN45, PPA, NF, 1016 x 305mm, 1/Pk XN45 Polypiperazine amide 1016 x 305 mm 1 5-7 days
$152.52
YMXN45475 TriSep Flat Sheet Membrane, XN45, PPA, NF, 47mm, 5/Pk XN45 Polypiperazine amide 47 mm 5 5-7 days
$83.88
1121998 TriSep Flat Sheet Membrane, XN45, PPA, NF, 90mm, 5/Pk XN45 Polypiperazine amide 90 mm 5 5-7 days
$227.93
1121056 TriSep Flat Sheet Membrane, XN45, PPA, NF, CF016, 5/Pk XN45 PPA CF016 5 5-7 days
$167.78
YMXN454205 TriSep Flat Sheet Membrane, XN45, PPA, NF, CF042, 5/Pk XN45 Polypiperazine amide CF042 5 5-7 days
$167.78
YMXN451905 TriSep Flat Sheet Membrane, XN45, PPA, NF, Sepa, 5/Pk XN45 Polypiperazine amide Sepa 5 5-7 days
$296.26
YMDKSP3001 Veolia Flat Sheet Membrane, DK, PA-TFC, NF, 305 x 305mm, 1/Pk DK Polyamide-TFC 305 x 305 mm 1 5-7 days
$99.94
YMDKSP475 Veolia Flat Sheet Membrane, DK, PA-TFC, NF, 47mm, 5/Pk DK Polyamide-TFC 47 mm 5 5-7 days
$83.88
1121948 Veolia Flat Sheet Membrane, DK, PA-TFC, NF, 90mm, 5/Pk DK Polyamide-TFC 90 mm 5 5-7 days
$227.93
1120987 Veolia Flat Sheet Membrane, DK, PA-TFC, NF, CF016, 5/Pk DK Polyamide-TFC CF016 5 5-7 days
$167.78
YMDKSP4205 Veolia Flat Sheet Membrane, DK, PA-TFC, NF, CF042, 5/Pk DK Polyamide-TFC CF042 5 5-7 days
$167.78
YMDKSP1905 Veolia Flat Sheet Membrane, DK, PA-TFC, NF, Sepa, 5/Pk DK Polyamide-TFC Sepa 5 5-7 days
$310.37
YMDLSP3001 Veolia Flat Sheet Membrane, DL, PA-TFC, NF, 305 x 305mm, 1/Pk DL Polyamide-TFC 305 x 305 mm 1 5-7 days
$99.94
YMDLSP475 Veolia Flat Sheet Membrane, DL, PA-TFC, NF, 47mm, 5/Pk DL Polyamide-TFC 47 mm 5 5-7 days
$83.88
1121950 Veolia Flat Sheet Membrane, DL, PA-TFC, NF, 90mm, 5/Pk DL Polyamide-TFC 90 mm 5 5-7 days
$227.93
1120988 Veolia Flat Sheet Membrane, DL, PA-TFC, NF, CF016, 5/Pk DL Polyamide-TFC CF016 5 5-7 days
$167.78
YMDLSP4205 Veolia Flat Sheet Membrane, DL, PA-TFC, NF, CF042, 5/Pk DL Polyamide-TFC CF042 5 5-7 days
$167.78
YMDLSP1905 Veolia Flat Sheet Membrane, DL, PA-TFC, NF, Sepa, 5/Pk DL Polyamide-TFC Sepa 5 5-7 days
$310.37
YMKHSP3001 Veolia Flat Sheet Membrane, Duracid NF, PA-TFC, NF, 305 x 305mm, 1/Pk Duracid NF Proprietary 305 x 305 mm 1 5-7 days
$109.45
YMKHSP475 Veolia Flat Sheet Membrane, Duracid NF, PA-TFC, NF, 47mm, 5/Pk Duracid NF Proprietary 47 mm 5 5-7 days
$83.88
1121952 Veolia Flat Sheet Membrane, Duracid NF, PA-TFC, NF, 90mm, 5/Pk Duracid NF Proprietary 90 mm 5 5-7 days
$227.93
1121000 Veolia Flat Sheet Membrane, Duracid NF, PA-TFC, NF, CF016, 5/Pk Duracid NF Proprietary CF016 5 5-7 days
$167.78
YMKHSP4205 Veolia Flat Sheet Membrane, Duracid NF, PA-TFC, NF, CF042, 5/Pk Duracid NF Proprietary CF042 5 5-7 days
$167.78
YMKHSP1905 Veolia Flat Sheet Membrane, Duracid NF, PA-TFC, NF, Sepa, 5/Pk Duracid NF Proprietary Sepa 5 5-7 days
$374.41
YMRLSP3001 Veolia Flat Sheet Membrane, RL, PA-TFC, NF, 305 x 305mm, 1/Pk RL Polyamide-TFC 305 x 305 mm 1 5-7 days
$99.94
YMRLSP475 Veolia Flat Sheet Membrane, RL, PA-TFC, NF, 47mm, 5/Pk RL Polyamide-TFC 47 mm 5 5-7 days
$83.88
1121954 Veolia Flat Sheet Membrane, RL, PA-TFC, NF, 90mm, 5/Pk RL Polyamide-TFC 90 mm 5 5-7 days
$227.93
1120997 Veolia Flat Sheet Membrane, RL, PA-TFC, NF, CF016, 5/Pk RL Polyamide-TFC CF016 5 5-7 days
$167.78
YMRLSP4205 Veolia Flat Sheet Membrane, RL, PA-TFC, NF, CF042, 5/Pk RL Polyamide-TFC CF042 5 5-7 days
$167.77
YMRLSP1905 Veolia Flat Sheet Membrane, RL, PA-TFC, NF, Sepa, 5/pk RL Polyamide-TFC Sepa 5 5-7 days
$374.40
per page
Set Descending Direction

Frequently Asked Questions

Yes—flat sheet membranes can be cut to fit your stirred cell. For best results, use the stirred cell support disk as a template to trace the correct size, then cut the membrane carefully to match.

Yes, we can supply the flat sheet membranes in the correct disk size for your stirred cell. Please contact us at [email protected] for pricing and availability.

Used flat sheet crossflow membranes must be stored wet at all times. If a membrane is allowed to dry out, it can irreversibly lose water permeability and performance.

For storage, place the membrane fully submerged in one of the following solutions:
0.5% formaldehyde solution (helps prevent microbial growth)
1.0% sodium metabisulfite (SMBS) solution -- Replace the SMBS solution monthly to maintain effectiveness

UPDI water (ultrapure deionized water)--Replace the water weekly to reduce contamination and biofouling

Yes, we are able to offer some of the flat sheet membranes as roll stock. Please contact us at [email protected] to inquire about pricing and availability.

Flow characteristics for a spiral element and flat sheet membrane are significantly different and are really only comparable on a qualitative basis. Variability in the membrane manufacturing process, differences in water composition, test procedures, and test equipment, used in a factory, laboratory, or elsewhere, will impact water flux results.

Reference: Understanding Variation of Experimental Flux and Rejection

We do not offer complimentary samples of the flat sheet crossflow membranes. However, most customers find the standard pack quantities to be quite reasonable for initial evaluations. For customers that want to evaluate several different membranes, we do offer custom variety packs. And, in some instances, we may be able to offer custom packs containing smaller sheet quantities. Please contact us to inquire about pricing and availability.

Sterlitech flat sheet crossflow membranes should be stored sealed in the original packaging in a climate-controlled environment, protected from direct light, heat, and temperature extremes. While we recommend using membranes as soon as practical after receipt, most flat sheet membranes can typically be stored for up to one (1) year without affecting performance when stored properly.

Some manufacturers supply their membrane in wet to prevent the membrane from going dry. There is always moisture in these sealed bags and it is not uncommon for some condensation (droplets) to form.
Rinsing the membrane on both sides with a stream of clean water is sufficient to remove the preservative solution. There is no need to pre-condition.
Yes, you need to pre-wet the membranes. The best procedure is to place them in a dry holder and allow them to wet from the inlet side first. It may be best to perform this operation with water or a buffer, then dispose of the first rinse, and introduce the process fluid. This prevents any wetting agents or preservatives from mixing with the process solution.
Yes, you may attempt to reuse flat sheet membranes. However, you may find it difficult to achieve a leak free seal. The cell body o-rings necessarily compress the membrane during installation and the physical action of separating the membrane from the o-rings during removal may cause damage. This damage can impede that ability to achieve a leak free seal when the membrane is reused.
Unfortunately, allowing a previously wetted crossflow membrane to dry usually results in permanent reduction of water permeability. Nevertheless, you can attempt to re-wet the membrane and use it. First, soak the membrane in a 50% alcohol solution for at least 15min (ethanol, methanol, or IPA would be acceptable). Next, install the membrane in the test cell and operate the cell with purified deionized water as though you were pre-conditioning the membrane. After about 30min, the permeate flux should stabilize to whatever rate the membrane is now capable of.
Determining which solution to use to clean a flat sheet membrane depends on the substance it is fouled with. As a general rule, you can use a caustic or oxidant solution for organic fouling and an acidic solution for inorganic causes. Please remember that different membranes polymers have different pH tolerances.
Yes, for flat sheet membranes that will be used with water or aqueous solutions, we recommend that you pre-condition the membranes prior to conducting your separation experiments. Pre-conditioning helps ensure that the membranes perform as expected. Also, pre-conditioning removes preservatives and other residuals from the membranes. Purified deionized water is used to pre-condition the membranes. For all flat sheet membranes except the forward osmosis (FO) membranes, install the membrane in the test cell and apply the purified deionized water feed at the normal operating rate and pressure for the membrane. Allow the system to operate with the purified deionized water feed until the permeate flux stabilizes at an expected value. You can now replace the purified deionized water feed with your feed solution and begin your experiments.
Most membrane manufacturers recommend CFVs of 5 to 35cm/s for their spiral wound membrane elements. The flat sheet membranes can be operated in this range to simulate use in such elements. Additionally, the flat sheet membranes may be operated outside of this range by users that want to examine the relationship between CVF and fouling and membrane performance in their applications.
Cross flow velocity (CFV) is the linear velocity of the feed flow tangential to the membrane surface and is typically reported in m/sec or ft/sec. It is calculated by dividing the volumetric flow rate through the feed channel by the cross-sectional area of the feed channel. Please refer to the CFV article at Tech Tips for more information.
The recommended TMP will depend on the type of flat sheet membrane and on the application. Typically, a reasonable TMP will be the same as that noted for the permeate flux specification of the membrane. The specifications for any of the flat sheet membranes can be easily found on our website by clicking the “application/specification” tab on the product web page and scrolling down as necessary. Please contact us at [email protected] if you need additional assistance.
These membrane sizes are intended for use in the bench-scale crossflow test cells offered by Sterlitech. Please see the list of flat sheet membranes we offer and their dimensions: HP4750 Stirred Cell: 47 mm (1.85") discs, CF016 cell: 58 x 75 mm (2.26 x 2.95") coupons, CF042 cell: 56 x 115 mm (2.20 x 4.53") coupons, Sepa CF cell: 140 x 190 mm (5.51 x 7.48") coupons, CF047 circular cell: 47 mm discs, CF090 circular cell: 90 mm discs

For a feed solution of 2,000 ppm sodium chloride (NaCl) at 70 psi (0.5 MPa) and 77°F (25°C), the NF90 membrane has sodium chloride rejection of between 90-96% while the NF270 membrane has approximately 50% rejection.

Frequently Asked Questions

Yes—flat sheet membranes can be cut to fit your stirred cell. For best results, use the stirred cell support disk as a template to trace the correct size, then cut the membrane carefully to match.

Yes, we can supply the flat sheet membranes in the correct disk size for your stirred cell. Please contact us at [email protected] for pricing and availability.

Used flat sheet crossflow membranes must be stored wet at all times. If a membrane is allowed to dry out, it can irreversibly lose water permeability and performance.

For storage, place the membrane fully submerged in one of the following solutions:
0.5% formaldehyde solution (helps prevent microbial growth)
1.0% sodium metabisulfite (SMBS) solution -- Replace the SMBS solution monthly to maintain effectiveness

UPDI water (ultrapure deionized water)--Replace the water weekly to reduce contamination and biofouling

Yes, we are able to offer some of the flat sheet membranes as roll stock. Please contact us at [email protected] to inquire about pricing and availability.

Flow characteristics for a spiral element and flat sheet membrane are significantly different and are really only comparable on a qualitative basis. Variability in the membrane manufacturing process, differences in water composition, test procedures, and test equipment, used in a factory, laboratory, or elsewhere, will impact water flux results.

Reference: Understanding Variation of Experimental Flux and Rejection

We do not offer complimentary samples of the flat sheet crossflow membranes. However, most customers find the standard pack quantities to be quite reasonable for initial evaluations. For customers that want to evaluate several different membranes, we do offer custom variety packs. And, in some instances, we may be able to offer custom packs containing smaller sheet quantities. Please contact us to inquire about pricing and availability.

Sterlitech flat sheet crossflow membranes should be stored sealed in the original packaging in a climate-controlled environment, protected from direct light, heat, and temperature extremes. While we recommend using membranes as soon as practical after receipt, most flat sheet membranes can typically be stored for up to one (1) year without affecting performance when stored properly.

Some manufacturers supply their membrane in wet to prevent the membrane from going dry. There is always moisture in these sealed bags and it is not uncommon for some condensation (droplets) to form.
Rinsing the membrane on both sides with a stream of clean water is sufficient to remove the preservative solution. There is no need to pre-condition.
Yes, you need to pre-wet the membranes. The best procedure is to place them in a dry holder and allow them to wet from the inlet side first. It may be best to perform this operation with water or a buffer, then dispose of the first rinse, and introduce the process fluid. This prevents any wetting agents or preservatives from mixing with the process solution.
Yes, you may attempt to reuse flat sheet membranes. However, you may find it difficult to achieve a leak free seal. The cell body o-rings necessarily compress the membrane during installation and the physical action of separating the membrane from the o-rings during removal may cause damage. This damage can impede that ability to achieve a leak free seal when the membrane is reused.
Unfortunately, allowing a previously wetted crossflow membrane to dry usually results in permanent reduction of water permeability. Nevertheless, you can attempt to re-wet the membrane and use it. First, soak the membrane in a 50% alcohol solution for at least 15min (ethanol, methanol, or IPA would be acceptable). Next, install the membrane in the test cell and operate the cell with purified deionized water as though you were pre-conditioning the membrane. After about 30min, the permeate flux should stabilize to whatever rate the membrane is now capable of.
Determining which solution to use to clean a flat sheet membrane depends on the substance it is fouled with. As a general rule, you can use a caustic or oxidant solution for organic fouling and an acidic solution for inorganic causes. Please remember that different membranes polymers have different pH tolerances.
Yes, for flat sheet membranes that will be used with water or aqueous solutions, we recommend that you pre-condition the membranes prior to conducting your separation experiments. Pre-conditioning helps ensure that the membranes perform as expected. Also, pre-conditioning removes preservatives and other residuals from the membranes. Purified deionized water is used to pre-condition the membranes. For all flat sheet membranes except the forward osmosis (FO) membranes, install the membrane in the test cell and apply the purified deionized water feed at the normal operating rate and pressure for the membrane. Allow the system to operate with the purified deionized water feed until the permeate flux stabilizes at an expected value. You can now replace the purified deionized water feed with your feed solution and begin your experiments.
Most membrane manufacturers recommend CFVs of 5 to 35cm/s for their spiral wound membrane elements. The flat sheet membranes can be operated in this range to simulate use in such elements. Additionally, the flat sheet membranes may be operated outside of this range by users that want to examine the relationship between CVF and fouling and membrane performance in their applications.
Cross flow velocity (CFV) is the linear velocity of the feed flow tangential to the membrane surface and is typically reported in m/sec or ft/sec. It is calculated by dividing the volumetric flow rate through the feed channel by the cross-sectional area of the feed channel. Please refer to the CFV article at Tech Tips for more information.
The recommended TMP will depend on the type of flat sheet membrane and on the application. Typically, a reasonable TMP will be the same as that noted for the permeate flux specification of the membrane. The specifications for any of the flat sheet membranes can be easily found on our website by clicking the “application/specification” tab on the product web page and scrolling down as necessary. Please contact us at [email protected] if you need additional assistance.
These membrane sizes are intended for use in the bench-scale crossflow test cells offered by Sterlitech. Please see the list of flat sheet membranes we offer and their dimensions: HP4750 Stirred Cell: 47 mm (1.85") discs, CF016 cell: 58 x 75 mm (2.26 x 2.95") coupons, CF042 cell: 56 x 115 mm (2.20 x 4.53") coupons, Sepa CF cell: 140 x 190 mm (5.51 x 7.48") coupons, CF047 circular cell: 47 mm discs, CF090 circular cell: 90 mm discs

For a feed solution of 2,000 ppm sodium chloride (NaCl) at 70 psi (0.5 MPa) and 77°F (25°C), the NF90 membrane has sodium chloride rejection of between 90-96% while the NF270 membrane has approximately 50% rejection.

Ask An Expert

As an industry leader focused in unique micro and sub-micron filtration products, our goal is to support our customers by keeping them at the forefront of their industries. We're here to help with any filtration questions you might have so you can transform your ideas into reality, and tackle those big science challenges. Feel free to reach out using the form below, our experts are ready to serve.